摘要
针对在核电厂控制室系统环境中操作员存在人为失误的风险,对影响主控制室操作员警觉性的各种因素分析,提出控制室系统环境设计建议,旨在提高操作员警觉性。
In view of the risk of human error for operators in the control room system environment of nuclear power plants,various factors affecting the alertness of the main control room operators are analyzed,and suggestions for the design of the control room system environment are proposed to improve the alertness of the operators.
作者
余周俊
张瑞萍
叶琳
吴茜
刘一鸣
Yu Zhoujun;Zhang Ruiping;Ye Lin;Wu Qian;Liu Yiming(Hualong Nuclear Power Technology Co.,Ltd.,Beijing,100036,China)
出处
《仪器仪表用户》
2022年第2期65-68,共4页
Instrumentation
关键词
核电厂
控制室系统
操作员警觉性
环境设计
nuclear power plants
control room system
operator alertness
environmental design