摘要 介绍航天炉生产合成氨装置深度变换系统投运后冷凝液中氨氮含量高,给整个装置连续稳定运行带来一系列严重问题,对此进行原因分析,并提出解决措施。通过优化改造后的生产实践,验证了为解决深度变换系统问题采取的措施和改造的科学性、合理性、经济性。 High concentration of ammonia nitrogen occurred in deep conversion system in HT-L gasifier synthetic ammonia plant after commissioning, which severely impacted on the continuous and stable operation of the whole plant. After analyzing the reasons, we put forward the solutions, which were optimized in the reformation during practical operation and verified to be scientific, reasonable and economical.
作者 柳兆忠 Liu Zhaozhong(Anhui Jingmei Zhongneng Chemical Co.,Ltd.,Fuyang 236400)
出处 《大氮肥》 CAS 2021年第6期425-428,共4页 Large Scale Nitrogenous Fertilizer Industry
关键词 航天炉 合成氨 深度变换 冷凝液 氨氮含量 碳洗塔结垢 常压汽提 HT-L gasifier synthetic ammonia deep conversion condensate ammonia nitrogen concentration fouling in carbon washing tower normal pressure stripping