摘要
传统的静电放电能量检测方法多依赖于经验公式,方法简单,计算误差较大。根据电压电荷法计算静电放电能量的原理,设计并搭建了实验系统,开发了基于MATLAB APP Designer的静电放电能量计算软件,并结合静电火灾事故调查实例验证其的科学性,为静电事故的预防与调查提供技术手段。
The traditional electrostatic discharge energy detection methods mostly rely on empirical formula,which is simple and has large calculation error.This paper designed and built an experimental system according to the principle of calculating electrostatic discharge energy by voltage charge method,developed the electrostatic discharge energy calculation software based on MATLAB APP Designer,and verified the scientific nature of this method by combining electrostatic accident investigation examples.It provides technical means for the prevention and investigation of electrostatic accidents.
作者
徐乐
娄仁杰
邹宜颖
王大伟
XU Le;LOU Ren-jie;ZOU Yi-ying;WANG Da-wei(School of Safety and Ocean Engineering,China University of Petroleum(Beijing),Beijing 102249,China;Dalian Branch,CNPC Research Institute of Safety and Environmental Technology,Liaoning Dalian 116031,China)
出处
《消防科学与技术》
CAS
北大核心
2021年第12期1848-1851,共4页
Fire Science and Technology
基金
国家重点研发计划课题(2017YFC0804703)。
关键词
静电放电
电压电荷法
事故调查
electrostatic discharge
voltage-charge method
accident investigation