期刊文献+

某水电站大轴补气管渗漏原因分析与处理

Analysis and Treatment of the Leakage of Air Supply Pipe for the Major Shaft in a Hydropower Station
下载PDF
导出
摘要 通过对某水电站机组在运行过程大轴补气管发生渗漏原因进行分析,对大轴补气管密封圈改造更换,成功消除了补气管密封损坏导致转子中心体渗水的重大缺陷,有效防止因其渗水引发转子绝缘降低造成机组事故停机事件的发生,提高了机组运行稳定性,为国内外同类型机组大轴补气管渗水检查处理积累了宝贵经验。 During the operation of units in a hydropower station,leakage of the air supply pipe for the major shaft is observed.Analysis shows that the problem is caused by the damage of the air supply pipe seal,which may lead to water leakage of the rotor center body.Then,the air supply pipe seal is replaced.The accidental shutdown of the unit caused by the reduction of the rotor insulation due to water leakage is effectively prevented,and the operation stability of the unit is improved.It provides valuable experience for the leakage inspection and treatment of the air supply pipe for the major shaft in similar units.
作者 胡畅 邓方雄 赵小明 HU Chang;DENG Fangxiong;ZHAO Xiaoming(China Guodian Dudu River Dagangshan Hydropower Development Co., Ltd., Shimian 625409, China)
出处 《水电与新能源》 2022年第1期51-53,共3页 Hydropower and New Energy
关键词 水电站 大轴补气管 渗漏 密封 处理 hydropower station air supply pipe for the major shaft leakage seal treatment
  • 相关文献

参考文献2

二级参考文献3

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部