摘要
青藏高原地区冬季寒冷且极端干燥,建筑冬季室内增温、加湿需求已同等迫切。本文在西藏拉萨市冬季条件下,对建筑室内湿源扩散特性进行大量实验测试分析,初步得到了加湿量、湿组分相态、湿组分温度和湿源位置等因素影响下室内湿度场的基本分布规律,为高原特殊气候条件下室内湿环境营造奠定了基础。
The Qinghai-Tibet Plateau is cold and extremely dry in winter,which makes the demand for indoor heating and humidification in winter is equally urgent.This paper conducted an experimental study on the diffusion of indoor moisture sources in Lhasa,Tibet,in winter,and initially identified the basic distribution law of the indoor humidity field under the influence of multiple factors,such as the humidification amount,the phase state and temperature of the wet component and the location of the source,providing a foundation for the construction of an indoor humidity environment under extreme climatic conditions on the plateau.
作者
胡家乐
王登甲
王莹莹
刘艳峰
HU Jiale;WANG Dengjia;WANG Yingying;LIU Yanfeng(Xi'an University of Architecture and Technology,Xi'an 710000,Shaanxi,China;State Key Laboratory of Green Building in Western China,Xi'an 710000,Shaanxi,China)
出处
《建筑科学》
CSCD
北大核心
2021年第12期15-22,共8页
Building Science
基金
国家自然科学基金面上项目“局部采暖热扩散空间递进分布机理及定向热环境设计关键参数研究”(52078408)
国家自然科学基金联合基金项目“高原藏区零能耗宜居建筑设计理论与关键技术研究”(U20A20311)
陕西省杰出青年科学基金项目“建筑节能与太阳能供暖”(2020JC-43)。
关键词
高原地区
低气压
室内湿环境
湿组分扩散
气液两相流
plateau area
low air pressure
indoor humidity environment
moisture diffusion
gas-liquid two-phase flow