期刊文献+

微波消解ICP-MS法测定清肺十八味丸中5种有害元素含量 被引量:1

Content determination of 5 harmful elements in Qingfei Shibawei Pills by microwave digestion ICP-MS
下载PDF
导出
摘要 目的建立电感耦合等离子体质谱法(ICP-MS)测定清肺十八味丸中铅(Pb)、汞(Hg)、镉(Cd)、铜(Cu)、砷(As)5种有害元素含量的方法。方法样品经微波消解,采用铋(Bi)、铑(Rh)、锗(Ge)为内标元素,以ICP-MS法进行测定。结果5种元素在各自浓度范围内线性关系良好(r>0.999),平均加样回收率在89.44%~96.68%,RSD在1.34%~2.74%(n=6),检出限在0.0002~0.0032 mg/kg。结论该方法简单、准确、灵敏度高,可用于测定清肺十八味丸中5种有害元素的含量。 Objective To establish a microwave digestion ICP-MS method for content determination of 5 harmful elements in Qingfei Shibawei Pills.Methods The samples were digested by microwave,and then determined by ICP-MS with Bismuth(Bi),Rhodium(Rh),Germanium(Ge)as the internal standard elements.Results The 5 elements showed good linear relationships within their own concentration ranges(r>0.999),and the average recoveries were 89.44%~96.68%,the RSDs were1.34%~2.74%(n=6),the LODs were 0.0002~0.0032 mg/kg.Conclusion The method is simple,accurate,sensitive,which can be used for the content determination of 5 harmful elements in Qingfei Shibawei Pills.
作者 赵猛 李玲 ZHAO Meng;LI Ling(Lianyungang Institute for Food and Drug Control,Lianyungang 222000,China)
出处 《中国处方药》 2022年第1期30-32,共3页 Journal of China Prescription Drug
关键词 微波消解 电感耦合等离子体质谱法 清肺十八味丸 有害元素 Microwave digestion ICP-MS Qingfei Shibawei Pills Harmful elements
  • 相关文献

参考文献13

二级参考文献173

共引文献225

同被引文献32

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部