期刊文献+

骨折创伤患者应用全自动凝血仪检测凝血功能的效果研究 被引量:3

Effect of Automatic Coagulation Instrument on Detecting Coagulation Function in Patients with Fracture and Trauma
下载PDF
导出
摘要 目的探讨全自动凝血仪检测骨折创伤患者凝血功能的效果。方法选取2020年1月—2020年8月医院骨折创伤患者337例作为骨折创伤组,另回顾性选取同期本院健康体检人员50例作为健康对照组,采用迈瑞ExC810全自动凝血仪及其配套试剂对两组人员的血浆D-二聚体(D-Dimer)、纤维蛋白原降解产物(FDP)及凝血四项(纤维蛋白原-Fbg、凝血酶原时间-PT、凝血酶时间-TT、活化部分凝血活酶时间-APTT)进行测定。统计分析两组人员的血浆D-Dimer、FDP水平、凝血四项,并统计分析骨折创伤组患者治疗前后的凝血四项。结果骨折创伤组患者的血浆D-Dimer、FDP水平均高于健康对照组(t=25.793,34.744,P<0.05)。骨折创伤组患者的血浆Fbg水平高于健康对照组(t=24.316,P<0.05),但两组人员的PT、TT、APTT之间的差异均不显著(t=1.448,0.532,2.709,P>0.05)。骨折创伤组患者治疗后的血浆Fg水平低于治疗前(t=47.583,P<0.05),但两组人员的PT、TT、APTT之间的差异均不显著(t=0.494,0.851,0.339,P>0.05)。结论全自动凝血仪能有效检测骨折创伤患者凝血指标,中医治疗效果好。 Objective To explore the effect of automatic coagulation instrument on detecting coagulation function in patients with fracture and trauma.Methods 337 patients with fracture and trauma in our hospital from January to August 2020 were retrospectively selected as the fracture and trauma group, and 50 healthy physical examination personnel in our hospital in the same period were retrospectively selected as the healthy control group. The plasma D-dimer, fibrinogen degradation product(FDP) and coagulation(fibrinogen Fbg Prothrombin time PT, thrombin time TT and activated partial thromboplastin time APTT) were measured. The levels of plasma D-dimer, FDP and coagulation in the two groups were statistically analyzed. The four items of coagulation before and after treatment in the fracture and trauma group were statistically analyzed.Results the levels of plasma D-dimer and FDP in fracture trauma group were higher than those in healthy control group(t=25.793, 34.744, P< 0.05). The level of plasma Fg in fracture trauma group was higher than that in healthy control group(t=24.316, P<0.05), but there was no significant difference in PT, TT and APTT between the two groups(t=1.448, 0.532, 2.709, P>0.05). The plasma FG level of fracture trauma group was lower than that before treatment(t=47.583,P<0.05), but there was no significant difference in PT, TT and APTT between the two groups(t=0.494, 0.851, 0.339, P>0.05).Conclusion automatic coagulation instrument is effective in detecting coagulation function in patients with fracture and trauma, Chinese medicine treatment effect is good.
作者 李焕英 郭庆昕 饶华春 许月霞 LI Huanying;GUO Qingxin;RAO Huachun;XU Yuexia(Fujian Quanzhou Bonesetting Hospital,Quanzhou 362000,Fujian,China)
机构地区 泉州市正骨医院
出处 《实用中医内科杂志》 2021年第12期56-58,共3页 Journal of Practical Traditional Chinese Internal Medicine
基金 福建省科技计划(2017Y0035)。
关键词 全自动凝血仪 骨折创伤 凝血功能 D-二聚体 纤维蛋白原降解产物 凝血四项 automatic coagulation instrument fracture trauma coagulation function D-dimer fibrinogen degradation products four items of coagulation
  • 相关文献

参考文献10

二级参考文献46

共引文献79

同被引文献32

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部