摘要 为提升水泥配料生产智能化水平,基于水泥生产工艺特点及在线检测技术发展,开发基于中子活化原理的水泥旁线元素分析仪自动配料系统。此系统通过对水泥物料元素的实时精确检测及自动配比调整,实现对水泥元素含量的稳定控制。经过现场应用验证,分析仪各元素测量精度较高,自动配料效果明显,能够有效指导生产,降低水泥生产成本,提升水泥质量。 In order to improve the intelligent level of cement proportion production,based on the characteristics of cement production process and the development of online analysis technology,an automatic proportion system of cement by-pass element analyzer based on neutron activation principle was developed.The system realizes the stable control of cement element content through real-time and accurate analysis of cement material element and auto proportion adjustment.The field application verification shows that the analyzer has high measuring accuracy of each element and obvious auto proportion effect,which can effectively guide the production,reduce the cost of cement production and improve the quality of cement.
出处 《中国水泥》 CAS 2022年第1期115-118,共4页 China Cement
基金 辽宁省劳模创新工作室 辽宁省科技重大专项计划项目(2020JH1/10100009)。
关键词 分析仪 水泥 元素 自动配料 Analyzer Cement Element Auto proportion
  • 相关文献

参考文献2

二级参考文献12

  • 1常富明.同位素仪表在氧化铝生产中的应用[J].轻金属,1994(11):21-23. 被引量:1
  • 2柴之芳.活化分析基础[M].北京:原子能出版社,1980..
  • 3Sudersanan M. Role of analytical techniques for characterisation of advanced and high purity materials [ J ].Progress in Crystal Growth and Characterization of Materials, 2002,44(3) : 189 ~ 194.
  • 4DDeSoete 伍任译.中子活化分析[M].北京:原子能出版社,1978.13-15,72-93.
  • 5Yasui M, Ota K, Sasajima K. Evaluation of calcium,magnesium, zinc, aluminum and manganese deposition in bones and CNS of rats fed calcium-deficient diets [J].Annual- Reports-of- t he-Research- Reactor- Institute, Kyoto Univ, Japan, 1994, 27:117~127.
  • 6David R C,John H F.Techniques ofin vivo neutron activation analysis[J].Phys Med Boil,1984,29(9):1011~1039.
  • 7林彭年.中子在线分析仪[J].金属矿山,1981(1):41-42.
  • 8罗邦富,魏明钟,沈祖炎,等.钢结构设计手册[M].北京:中国建筑工业出版社,1993.
  • 9侯新生,马英杰,方方,邱元德,周蓉生.中子活化分析在煤质分析中的应用[J].核技术,2001,24(4):264-268. 被引量:22
  • 10范方禄,张群.中子活化分析仪在石灰石预均化系统的应用[J].水泥,2001(12):43-44. 被引量:3

共引文献32

同被引文献10

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部