摘要 [目的]测量中老年人腰椎经皮椎弓根皮质骨螺钉的解剖学参数并分析其经皮置钉可行性。[方法]选取50例中老年人腰椎三维CT资料并导入Aquarius iNtuition Viewer V 4.4.6软件,测量各节段皮质骨螺钉置钉横断面与矢状面的进钉角度、安全范围、钉道直径及长度、螺钉轨迹皮肤进钉点至椎体上终板的距离和进钉点至棘突轴线的距离。[结果]L_(1-5)螺钉轨迹皮肤进钉点至椎体上终板的距离差异无统计学意义(P>0.05),进钉点至棘突轴线的距离差异有统计学意义(P<0.05)。横断面上L_(1-5)各节段的钉道直径逐渐增大,差异具有统计学意义(P<0.05);各节段的钉道实际长度差异有统计学意义(P<0.05),男性各节段钉道实际长度大于女性,差异有统计学意义(P<0.05);腰椎各节段钉道理想外偏角较一致,差异无统计学意义(P>0.05)。矢状面上L_(1-5)各节段钉道直径逐渐减小,差异具有统计学意义(P<0.05),腰椎各节段钉道直径性别差异无统计学意义(P>0.05)。L_(1-5)各节段钉道理想头倾角差异无统计学意义(P>0.05),各节段钉道理想头倾角性别差异无统计学意义(P>0.05)。[结论]通过至椎体上终板及至棘突中线的距离可找出经皮椎弓钉皮质轨迹螺钉的体表定位点,其在各节段间存在差异,该点可为中老年人腰椎经皮椎弓根皮质骨轨迹螺钉置人提供参考。 [Objective]To measure the anatomical parameters of cortical bone trajectory(CBT)for lumbar percutaneous pedicle cortical placement in middle-aged and elderly persons,and explore the feasibility of CBT percutaneous screw placement.[Methods]The three-dimensional CT data obtained from 50 middle-aged and elderly persons were imported into Aquarius iNtuition Viewer V4.4.6 software.The screw insertion angle,safety range,diameter and length of the nail path,the distance between skin screw insertion point and vertebral upper endplate and the distance between screw insertion point and spinous process axis were measured.[Results]There was no significant difference in the distance from the skin entry point to the vertebral upper endplate(P>0.05),whereas there was significant difference in the distance from the skin entry point to the spinous process axis from L1 to L5(P<0.05).In transvers plane,the diameters of the nail path gradually increased from L1 to L5,which was statistically significant(P<0.05).The actual length of the nail path in different segments was of statistical significance(P<0.05),which in the male proved significantly greater than that in the female segments(P<0.05).The ideal external deviation angles of the nail path in each segment of lumbar spine remained consistent,with no significant differences(P>0.05).In sagittal plane,the diameters of the nail path gradually decreased from L1 to L5,which was statistically significant(P<0.05),while no significant differences in the diameters of the nail path were found between two genders(P>0.05).The ideal cephalad inclination angle remained unchanged from L1 to L5(P>0.05),and was not significantly different between the two genders(P>0.05).[Conclusion]From the upper endplate of vertebral body to the midline of spinous process,a body surface positioning point for CBT percutaneous pedicle screw might be assured,which varies among different segments.This point can provide reference for the CBT percutaneous pedicle screw placement in middle-aged and elderly people.
作者 徐伟杰 朱云鹏 王洪伟 项良碧 XU Wei-jie;ZHU Yun-peng;WANG Hong-wei;XIANG Liang-bi(Postgraduate Training Base of Jinzhou Medical University;Postgraduate Training Base of China Medical University;Department of Orthopaedics,General Hospital of CPLA Northern Theater Command,Shenyang 110016,China)
出处 《中国矫形外科杂志》 CAS CSCD 北大核心 2022年第1期63-68,共6页 Orthopedic Journal of China
关键词 影像解剖测量 皮质骨轨迹螺钉 微创手术 经皮椎弓根固定 radiographically anatomic measurement cortical bone trajectory minimally invasive surgery percutaneous pedicle screw fixation
  • 相关文献

参考文献3

二级参考文献29

  • 1靳安民,姚伟涛,张辉,闵少雄,周初松,舒小秋,朱立新.腰椎内固定翻修术的初步研究[J].中华骨科杂志,2004,24(9):525-529. 被引量:33
  • 2侯树勋,史亚民.国人下胸椎及腰椎椎弓根形态学特点及其临床意义[J].中华骨科杂志,1994,14(4):222-225. 被引量:85
  • 3唐杞衡,陈建海,姜保国,张殿英,傅中国.椎弓根螺钉把持椎弓根皮质骨对其固定强度的影响[J].中国脊柱脊髓杂志,2005,15(7):429-432. 被引量:12
  • 4Santoni BG, Hynes RA, McGilvray KC, et al. Cortical bone trajectory for lumbar pedicle screws[J]. SpineJ, 2008, 9(5): 366-373.
  • 5Wittenberg RH, Shea M, Swartz DE, et al. Importance of bone mineral density in instrumented spine fusions[J]. Spine (Phila Pa 1976), 1991, 16(6): 647-652.
  • 6Davne SH, Myers DL. Complications of lumbar spinal fusion with transpedicular instrumentation[J]. Spine (Phila Pa 1976), 1992, 17 (6 Suppl): SI84-189.
  • 7Halvorson TL, Kelley LA, Thomas KA, et al. Effects of bone mineral density on pedicle screw fixation[J]. Spine (Phila Pa 1976), 1994,19(21): 2415-2420.
  • 8Calvert GC, Lawrence BD, Abtahi AM, et al. Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis[J].J Neurosurg Spine, 2014,22(2): 1-7.
  • 9Ueno M, Sakai R, Tanaka K, et al. Should we use cortical bone screws for cortical bone trajectory?[J].J Neurosurg Spine, 2015, 22(4): 1-6.
  • 10Mobbs RJ. The "medio-Iatero-superior trajectory technique": an alternative cortical trajectory for pedicle fixation[J]. Orthop Surg, 2013,5(1): 56-59.