采用统一操作方法E-Cervix技术评估孕中晚期宫颈弹性 被引量:3

Unified operating method of E-Cervix technology for evaluation on cervical elasticity in the second and third trimester of pregnancy
下载PDF
导出
摘要 目的评价以统一操作方法E-Cervix技术测量孕中晚期孕妇宫颈弹性参数的一致性。方法将160名孕中晚期孕妇分为宫颈内口闭合组(n=80)及开放组(n=80),于其中各随机选取40名作为统一操作亚组,其余40名为非统一操作亚组。由2名超声医师对各亚组孕妇行E-Cervix检查,测量宫颈弹性参数,包括弹性对比指数(ECI)、硬度比值(HR)、宫颈内口应变(IOS)、宫颈外口应变(EOS)、宫颈内外口应变比(IOS/EOS)及宫颈长度(CL)。采用组内相关系数(ICC)评价观察者内测量结果的一致性;如操作后每名医师测得各亚组内全部参数的ICC均≥0.6,则以Bland-Altman法评价观察者间测量参数的一致性。结果非统一操作时,每名医师测得每组部分参数ICC<0.6(P均<0.05);采用统一方法操作,每名医师测得参数的ICC均>0.8(P均<0.05)。统一操作后,Bland-Altman分析显示观察者间测量参数的一致性良好,各参数差值中95%~100%位于95%一致性界限内,差值的均值、回归方程的截距与斜率均无统计学意义(P均>0.05)。结论以统一方法行孕中晚期E-Cervix检查,所测宫颈弹性参数结果的一致性较高。 Objective To observe the consistency of unified operating method E-Cervix technology for evaluation on cervical elasticity of pregnancy women in the second and third trimester.Methods A total of 160 pregnant women in the second and third trimester of pregnancy were enrolled and divided into closed internal cervix orifice group(n=80)or open group(n=80).Pregnant women in each group were randomly further divided into unified operating subgroup or non-uniform operating subgroup(each n=40).E-Cervix examination was performed by 2 sonographers to measure cervical elasticity parameters,including elastic contrast index(ECI),hardness ratio(HR),internal os strain(IOS),external or strain(EOS),internal and external strain ratio(IOS/EOS)and cervical length(CL).The intra-class correlation coefficient(ICC)was used to evaluate the intra-observer consistency of the measurement results.Under the condition of ICC of all parameters measured by each sonographer≥0.6,the Bland-Altman method was used to analyze the inter-observer consistency of the measurement results of the above parameters.Results Using non-uniform operating method,the ICC of some parameters measured by each sonographer were<0.6(all P<0.05),whereas using unified operating method,the ICC of all parameters measured by each sonographer were>0.8(all P<0.05).Bland-Altman method analysis exhibited good inter-observer consistency of the measured parameters using unified operating method.There were 95%-100%points of the differences of parameters within 95%limits of agreement.The mean of the differences and the intercept and slope of the regression equation were not statistically different(all P>0.05).Conclusion Using unified operating method of E-Cervix might obtain good consistency of measurement results of cervical elasticity parameters of pregnancy women in the second and third trimester.
作者 郭玉娟 王睿丽 高园 张小林 刘冰冰 陈娟 袁建军 武海英 王莉 GUO Yujuan;WANG Ruili;GAO Yuan;ZHANG Xiaolin;LIU Bingbing;CHEN Juan;YUAN Jianjun;WU Haiying;WANG Li(Department of Ultrasound,Henan Provincial People's Hospital,Zhengzhou 450003,China;Department of Obstetrics,Henan Provincial People's Hospital,Zhengzhou 450003,China)
出处 《中国医学影像技术》 CSCD 北大核心 2022年第2期252-256,共5页 Chinese Journal of Medical Imaging Technology
关键词 子宫颈 超声检查 弹性成像技术 cervix uteri ultrasonography elasticity imaging techniques
  • 相关文献

参考文献4

二级参考文献16

共引文献44

同被引文献25

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部