摘要 Health monitoring of structures and people requires the integration of sensors and devices on various 3D curvilinear,hierarchically structured,and even dynamically changing surfaces.Therefore,it is highly desirable to explore conformal manufacturing techniques to fabricate and integrate soft deformable devices on complex 3D curvilinear surfaces.Although planar fabrication methods are not directly suitable to manufacture conformal devices on 3D curvilinear surfaces,they can be combined with stretchable structures and the use of transfer printing or assembly methods to enable the device integration on 3D surfaces.Combined with functional nanomaterials,various direct printing and writing methods have also been developed to fabricate conformal electronics on curved surfaces with intimate contact even over a large area.After a brief summary of the recent advancement of the recent conformal manufacturing techniques,we also discuss the challenges and potential opportunities for future development in this burgeoning field of conformal electronics on complex 3D surfaces.
出处 《International Journal of Extreme Manufacturing》 SCIE EI 2021年第4期1-21,共21页 极端制造(英文)
基金 This research is supported by the National Science Foundation(Grant No.ECCS-1933072) the Doctoral New Investigator grant from the American Chemical Society Petro-leum Research Fund(59021-DNI7) the National Heart,Lung,And Blood Institute of the National Institutes of Health under Award Number R61HL154215,and Penn State University.
  • 相关文献

参考文献7

二级参考文献50

  • 1S.-W. Hwang, H. Tao, D.-H. Kim, et al., A physically transient form of silicon electronics, Science 337 (2012) 1640-1644. http:/lwww.sciencemag.org/content/337/6102/1640.
  • 2S,W. Hwang, G. Park, H. Cheng, et al., 25th anniversary article: Materials for high-performance biodegradable semiconductor devices, Adv. Mater. 26 (2014) 1992-2000. http://onlinelibrary.wiley.com/doi/10.1002/adma.201470082/abstract.
  • 3R.O. Darouiche, Treatment of infections associated with surgical implants, N. Engl.]. Med. 350 (2004) 1422-1429. http://www.nejm.org/doi/fu]l/lO.1056/NEJMra035415.
  • 4H. Tao, S.-W. Hwang, B. Marel]i, et aL, Silk-based resorbable electronic devices for remotely controlled therapy and in vivo infection abatement, Proc. Natl. Acad. Sci. 111 (2014) 17385-17389. http:f/www.pnas.org/content/111/49/I 7385.abstract.
  • 5C. Dagdeviren, S.W. Hwang, Y. Su, et al., Transient, biocompatible electronics and energy harvesters based on ZnO, Small 9 (2013) 3398-3404. http:/jonlinelibrary.wiley.com/doi/10.1002/smll.201300146/abstract.
  • 6H.L Hernandez, S.K. Kang, O,P. Lee, et al., Triggered transience of metastable poly (phthalaldehyde) for transient electronics, Adv. Mater. 26 (2014) 7637-7642. http : / /onlinelibrary.wiley.com/ doi/ I O.1002 {adma.2014030451abstract.
  • 7C.H. Lee, S.K. Kang, G.A. Salvatore, et al., Wireless microfluidic systems for programmed, functional transformation of transient electronic devices, Adv. Funct. Mater. 25 (2015) 5100-5106. http://onlinelibrary.wiley.com/doi/10. 1002/adfm.201502192/abstract.
  • 8C.W. Park, S.K. Kang, H.L. Hernandez, et al., Thermally triggered degradation of transient electronic devices, Adv. Mater. 27 (2015) 3783-3788. http : / /onlinelibrary. wiley.com/ doi /10.1002 / adma.201501180 /abstract.
  • 9X. Huang, Y. Liu, S.W. Hwang, et al., Biodegradable materials for multilayer transient printed circuit boards, Adv. Mater. 26 (2014) 7371-7377. http:l/onlinelibrary.wiley.com/doi/10.1002[adma.201403164/abstract.
  • 10S.W. Hwang, S.K. Kang, X. Huang, et al., Materials for programmed, functional transformation in transient electronic systems, Adv. Mater. 27 (2015) 47-52. http://onlinelibrary.wiley.com/doi/10.1002/adma.20140305 I/abstract.

共引文献59

同被引文献7

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部