期刊文献+

气囊型输液港防水保护背心在胸壁植入输液港病人洗澡中的应用 被引量:1

下载PDF
导出
摘要 目的:探讨气囊型输液港防水保护背心在胸壁植入输液港病人洗澡中的应用效果。方法:选择胸壁植入输液港病人100例为研究对象,按病人洗澡时输液港保护方法的不同分为对照组与观察组各50例,对照组病人洗澡时采用保鲜膜包裹法,观察组病人洗澡时采用气囊型输液港防水保护背心防护。比较两组病人洗澡后胸壁输液港植入部位潮湿情况、病人舒适度、换敷料间隔时间、输液港植入部位感染发生情况。结果:观察组病人洗澡后胸壁输液港植入部位潮湿发生率明显低于对照组(P<0.05);观察组病人舒适度明显高于对照组(P<0.05);观察组病人敷料更换间隔时间明显长于对照组(P<0.05);观察组病人输液港植入部位感染发生率明显低于对照组(P<0.05)。结论:气囊型输液港防水保护背心防水性能较好,在胸壁植入输液港病人洗澡时应用能解决输液港敷料的防水保护问题,提高病人舒适度,延长敷料更换间隔时间,降低输液港植入部位感染发生率。
作者 何梅 周丽文
机构地区 中山市人民医院
出处 《全科护理》 2022年第5期632-633,共2页 Chinese General Practice Nursing
关键词 气囊型 防水 输液港 保护背心 airbag type waterproof implantable venous access port protective vest
  • 相关文献

参考文献6

二级参考文献37

  • 1Silberzweig JE,Sacks D,Khorsandi AS. Reporting standards for central venous access.Technology Assessment Committee[J].JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY,2000,(03):391-400.
  • 2Hinke DH,Zandt-Stastny DA,Goodman LR. Pinch-off syndrome:a complication of implantable subclavian venous access devices[J].RADIOLOGY,1990,(02):353-356.
  • 3Surov A,Wienke A,Carter JM. Intravascular embolization of venous catheter--causes,clinical signs,and management:a systematic review[J].JPEN Journal of Parenteral and Enteral Nutrition,2009,(06):677-685.
  • 4Osawa H,Hasegawa J,Yamakawa K. Ultrasound-guided infraclavicular axillary vein puncture is effective to avoid pinch-off syndrome:a long-term follow-up study[J].SURGERY TODAY-THE JAPANESE Journal OF SURGERY,2012,(07):745-750.
  • 5Vescia S,Baumg?rtner AK,Jacobs VR. Management of venous port systems in oncology:a review of current evidence[J].ANNALS OF ONCOLOGY,2008,(01):9-15.
  • 6Wolosker N,Yazbek G,Nishinari K. Totally implantable venous catheters for chemotherapy:experience in 500 patients[J].Sao Paulo Medical Journal:Revista Paulista de Medicina,2004,(04):147-151.
  • 7Barbetakis N,Asteriou C,Kleontas A. Totally implantable central venous access ports.Analysis of 700 cases[J].Journal of Surgical Oncology,2011,(06):654-656.
  • 8Grannan KJ,Taylor PH. Early and late complications of totally implantable venous access devices[J].Journal of Surgical Oncology,1990,(01):52-54.
  • 9Trerotola SO,Kuhn-Fulton J,Johnson MS. Tunneled infusion catheters:increased incidence of symptomatic venous thrombosis after subclavian versus internal jugular venous access[J].RADIOLOGY,2000,(01):89-93.
  • 10Schwarz RE,Groeger J,Coit DG. Subcutaneously implanted central venous access devices in cancer patients:A prospective analysis[J].CANCER,1997,(08):1635-1640.

共引文献81

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部