期刊文献+

风电场单桩竖向极限承载力估算方法对比分析 被引量:1

Comparative Analysis of Estimation Methods for Vertical Ultimate Bearing Capacity of Single Pile in Wind Farm
下载PDF
导出
摘要 单桩竖向极限承载力是风电场桩基设计的重要依据。JGJ 94-2008《建筑桩基技术规范》给出了混凝土预制桩单桩竖向极限承载力标准值的经验参数法和静力触探法两种估算方法。文章以平原风电场为例,详细阐述了在饱和软弱土中两种估算方法结果的差异,分析了差异性的原因,得出了双桥静探法获取地质数据和估算成果精确度高,且估算成果大于经验参数法,经验参数法估算结果误差较大且偏于保守,提出以双桥静探法作为估算单桩竖向极限承载力的主要方法,并建议根据地区静载荷试验验证和修正,使成果更符合当地实际。 The vertical ultimate bearing capacity of a single pile is an important basis for the design of pile foundations in wind farms.In JGJ-94-2008"Technical Code for Building Pile Foundations",two estimation methods are presented:the empirical parameter method and the static cone penetration method for the standard value of the vertical ultimate bearing capacity of a single precast concrete pile.Taking a plain wind farm as an example,the difference between the results estimated by the two methods in saturated soft soil is explained and the cause for the difference is analyzed,and the result is that the double-bridge static penetration method is more accurate in obtained geological data and estimation results and the estimation results are greater than that of the empirical parameter method;the empirical parameter method is of larger errors and its estimation results are more conservative.The double-bridge static penetration method is proposed as the main method for estimating the vertical ultimate bearing capacity of a single pile.The results shall be checked and modified to be in line with local practice.
作者 梁海 赵志祥 胡向阳 韩建军 杨飞 LIANG Hai;ZHAO Zhixiang;HU Xiangyang;HAN Jianjun;YANG Fei(PowerChina Northwest Engineering Corporation Limited, Xi'an 710065, China;Inner Mongolia Chahar New Energy Co., Ltd., Ulan Qab 012000,China)
出处 《西北水电》 2021年第6期49-53,共5页 Northwest Hydropower
关键词 风电场 饱和软弱土 双桥静探法 经验参数法 单桩竖向极限承载力 wind farm saturated soft soil double-bridge static penetration method empirical parameter method vertical ultimate bearing capacity of single pile
  • 相关文献

参考文献9

二级参考文献26

  • 1张明远,钟珞.基于GA-BP神经网络的单桩承载力预测[J].武汉理工大学学报,2008,30(3):86-89. 被引量:9
  • 2赵春风,蒋东海,崔海勇.单桩极限承载力的静力触探估算法研究[J].岩土力学,2003,24(S2):408-410. 被引量:18
  • 3GB50021-2001.岩土工程勘察规范[S].[S].,2002..
  • 4中华人民共和国住房和城乡建设部.JGJ94-2008建筑桩基技术规范[S].北京:中国建筑工业出版社,2008.
  • 5中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.GB13467-2009先张法预应力混凝土管桩[S].北京:中国标准出版社,2010.
  • 6陈强华 陈国铨.静力触探估算打入桩的单桩承载力.同济大学学报,1984,(4).
  • 7GB50007-2002.建筑地基基础设计规范[S].[S].,..
  • 8地基处理手册编写委员会.地基处理手册(第二版)[M].北京,中国建筑工业出版社,1999.
  • 9JGJ 94-2008,建筑桩基技术规范[S].
  • 10黄强,刘金砺,高文生,等.JGJ94-2008,建筑桩基技术规范.北京:中国建筑工业出版社,2008;19_O.