摘要
基于某核电厂堆外核测量系统设备信号线缆电快速瞬变脉冲群抗扰度(EFT)试验不通过的情况,对电快速瞬变脉冲群抗扰度试验以及干扰机理进行研究。结果表明,对信号线缆增加一定屏蔽效能的屏蔽网并对屏蔽网接地能有效抑制干扰信号。为堆外核测量系统以及同类产品EFT试验提供指导,同时为后续项目电缆选型提供参号。
Based on the failure of the electrical fast transient/burst immunity(EFT)test for the Extra-reactor nuclear measurement system’s signal cable,the analysis of the EFT has been carries out.The result shows that measures by adding shielding on the signal cable and grounding are effective for suppress interference signal.It provides reference for the similar products’EFT test and cable selection.
作者
汪建明
杨静远
王小雨
贺先建
杨戴博
曾少立
WANG Jian-ming;YANG Jing-yuan;WANG Xiao-yu;HE Xian-jian;YANG Dai-bo;ZENG Shao-li(Science and Technology on Reactor System Design Technology Laboratory,Nuclear Power Institute of China,Chengdu 610213,China;Nuclear and Radiation Safety Center,Beijing 100082,China)
出处
《核电子学与探测技术》
CAS
北大核心
2021年第4期718-723,共6页
Nuclear Electronics & Detection Technology
关键词
堆外核测量系统
电快速瞬变脉冲群抗扰度试验
Extra-Reactor Nuclear Measurement System
Electrical Fast Transient/Burst Immunity Test