期刊文献+

Diagnosing early scar pregnancy in the lower uterine segment after cesarean section by intracavitary ultrasound 被引量:5

下载PDF
导出
摘要 BACKGROUND Early scar pregnancy(CSP)in the lower uterine segment after cesarean section is a type of ectopic pregnancy that can cause major complications if left untreated.Transabdominal ultrasound is a common procedure but is influenced by external factors.Thus,intracavitary ultrasound may have better diagnostic efficiency for CSP.AIM To assess the value of intracavitary ultrasound for diagnosing CSP in the lower uterine segment after cesarean section.METHODS Patients diagnosed with CSP in our hospital from October 2019 to April 2021 were recruited.Transabdominal and intracavitary ultrasound examinations were performed to compare the diagnostic differences for CSP and its types.RESULTS Sixty-three patients were diagnosed during the study period.The diagnostic accuracy for CSP was higher in intracavitary ultrasound(96.83%)than in transabdominal ultrasound(84.13%)(P<0.05).The missed diagnosis and misdiagnosis rates did not differ among the ultrasound types(intra:0.00%and 3.17%;trans:4.76%and 11.11%,respectively;P>0.05).For the diagnostic rates for the CSP types,the rates for gestational sac(100.00%vs 90.48%),heterogeneous mass(93.75%vs 75.00%),and part of the uterine cavity(80.00%vs 60.00%)were higher in intracavitary ultrasound than in transabdominal ultrasound,but the difference was not statistically significant(P>0.05).For gestational sac CSP patients,intracavitary ultrasound showed that the gestational sac was located in the lower uterine segment scar with abundant peripheral blood flow;the distance between the gestational sac and the serosal layer was 2.42±0.50 cm.Intracavitary ultrasound for heterogeneous mass CSP patients indicated that the mass mainly occurred in the lower anterior uterine wall,protruding into the bladder,and was surrounded by abundant internal and peripheral blood flow;the distance between the mass and serosal layer was 1.79±0.30 cm.For CSP type partly located in the uterine cavity,the gestational sac was partly located in the lower uterine cavity and partly in the scar with abundant internal and peripheral blood flow;the distance between the gestational sac and the serosal layer was 2.29±0.28 cm.CONCLUSION Intracavitary ultrasound had a higher diagnostic accuracy and application value for diagnosing CSP than transabdominal ultrasound,with reduced risk of missed diagnoses and misdiagnosis,thereby preventing delayed treatment.
出处 《World Journal of Clinical Cases》 SCIE 2022年第2期547-553,共7页 世界临床病例杂志
  • 相关文献

同被引文献63

引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部