高层住宅楼梯间自然通风防烟措施可靠性分析

RELIABILITY ANALYSIS OF NATURAL VENTILATION AND SMOKE CONTROL MEASURES BASED ON STAIRCASE OF HIGH-RISE RESIDENTIAL BUILDINGS
下载PDF
导出
摘要 通过对已建并投入使用的高层住宅建筑防烟楼梯间所采用自然通风的防烟措施现状进行实地调研,充分了解自然防烟措施在实践过程中所存在的问题。对"被动式可开启防烟窗"措施的可靠性进行分析,对现有实际存在的问题进行探讨。研究发现在发生火灾突然事情人员疏散过程中,人的因素很大程度上影响自然防烟的有效性,并提出相应解决办法,提高火灾紧急情况下,安全疏散区域的防烟措施的可靠性。 Through the field investigation of the status quo of the natural ventilation smoke control measures used in the smoke control staircases of high-rise residential buildings that have been built and put into use, we can fully understand the problems existing in the practice of the natural smoke control measures. The paper analyzes the reliability of passive openable smoke proof window, and discusses the existing problems. It is found that in the process of fire emergency evacuation, human factors greatly affect the effectiveness of natural smoke control, and the corresponding solutions are proposed to improve the reliability of smoke control measures in the safe evacuation area in case of fire emergency.
作者 胡习博 孙小平 Hu Xi-bo;Sun Xiao-ping
出处 《建筑技术开发》 2022年第1期102-105,共4页 Building Technology Development
关键词 建筑防火 自然排烟 安全疏散 可开启防烟窗 被动式 主动式 building fire prevention natural smoke exhaust safe evacuation openable smoke window passive active
  • 相关文献

参考文献4

二级参考文献21

  • 1刘朝贤.高层建筑房间可开启外窗朝向数量对自然排烟可靠性的影响.制冷与空调,2007,.
  • 2刘朝贤.对高层建筑房间自然排烟极限高度的探讨.制冷与空调,2007,.
  • 3刘朝贤.高层建筑防烟楼梯间自然排烟的可行性探讨.制冷与空调,2007,.
  • 4刘朝贤.对《高层民事建筑设计防火规范》第8.2.3条的解析与商榷.制冷与空调,2007,.
  • 5刘朝贤.对加压送风防烟方案的优化分析与探讨[C]//全国暖通空调制冷2008年学术年会论文集,2008.
  • 6中华人民共和国城乡建设环境保护部.JGJ 35-87 (试行)建筑气象参数标准[S].北京:中国建筑工业出版社,1987.
  • 7中国气象局信息中心气象资料室,清华大学建筑技术科学系.中国建筑热环境分析专用气象数据集[M].北京:中国建筑工业出版社,2005
  • 8中华人民共和国公安部.GB 50045-95 高层民用建筑设计防火规范[S].北京:中国计划出版社,2005
  • 9刘朝贤.高层建筑加压送风防烟系统软、硬件部分可靠性分析[J].暖通空调,2007,37(11):74-80. 被引量:12
  • 10陆耀庆.《实用供热空调设计手册》修编信息[J].暖通空调,2008,38(1):1-1. 被引量:27