摘要 介绍了反渗透系统运行参数标准化产水量、标准化脱盐率和标准化压差等3个模型的建立,并通过标准化的产水量、跨膜压差和脱盐率与实际的数据对比来反映反渗透系统的运行状况,为反渗透系统的运行管理提供参考。 This paper introduces the establishment of three models of standardized water yield,standardized desalination rate and standardized differential pressure of reverse osmosis system operation parameters,and reflects the operation condition of reverse osmosis system by comparing the standardized water yield,transmembrane differential pressure and desalination rate with the actual data,which provides reference for the operation management of reverse osmosis system.
作者 段小冰 DUAN Xiaobing(Beijing Shougang Qianan Iron and Steel Co.,Ltd.,Qianan,Hebei 064404,China)
出处 《冶金动力》 2022年第1期89-92,共4页 Metallurgical Power
关键词 反渗透 标准化 压差 脱盐率 reverse osmosis standardization differential pressure desalination rate