摘要
阐述了高压加热器泄漏的现象及对发电机组的影响,针对抽汽逆止门和电动门关闭不严密引起汽轮机进水、汽轮机上下缸温差大、动静摩擦等故障的潜在风险,提出了高压加热器泄漏预防措施,以保证机组安全稳定运行。
The leakage of high-pressure heater and its influence on the power units are described.In view of the potential failure risks including steam turbine ingress,excessive temperature difference between the upper and lower cylinders of turbine,and dynamic and static frictions,etc.Due to the poor tightness of extraction check valves and motor-driven doors,and the preventive measures against leakage of high-pressure heaters are put forward so as to ensure the safe and stable operation of units.
作者
李衍平
LI Yanping(Laicheng Power Plant of Huadian Power International Co.,Ltd.,Jinan 271100)
出处
《电力安全技术》
2022年第1期20-22,共3页
Electric Safety Technology
关键词
火力发电
汽轮机
加热器泄漏
振动
coal-fired power
steam turbine
heater leakage
vibration