摘要
针对某350 MW超临界直接空冷机组背压异常上升、抽真空管道温度始终偏低问题,详细阐述了事件现象与经过,分析了背压异常上升的原因,确定为真空泵前置冷却器疏水不畅水位高导致,及时采取相应措施后背压恢复正常,对此类问题提出了相应建议与预防措施。
In view of the abnormal rise of back pressure and low vacuum pipe temperature of a 350 MW supercritical direct air cooling unit,the event phenomenon and process is described,and the reasons are analyzed.It is caused by poor drainage of vacuum pump pre-cooler and high water level.Back pressure returns to normal after taking corresponding measures in time,and corresponding suggestions and preventive measures are put forward for such problems.
作者
王利伟
王涛
张鹏
吕蒙
WANG Li-wei;WANG Tao;ZHANG Peng(Xi'an Branch of North China Electric Power Research Institute Co.,Ltd.)
出处
《电站系统工程》
2022年第1期56-58,61,共4页
Power System Engineering
关键词
直接空冷
背压
前置冷却器
事故分析
direct air-cooled
back pressure
pre-cooler
accident analysis