期刊文献+

400 kA铝电解槽停槽降低黑电压的研究与实践 被引量:1

Study and Practice on Shutdown Black Voltage Decreasing for 400 kA Aluminum Reduction Cell
下载PDF
导出
摘要 针对停槽黑电压高、整流效率低、空耗大、吨铝电耗高的问题,采取了多安装一条或多条跨接母线,降低单台槽母线总电阻的措施,达到了降低停槽黑电压、无功空耗及生产成本的目的。通过安装跨接母线,停槽电解槽平均每台槽降低黑电压79.3 mV,每槽每天平均可节约319元。 One or several jumper bus bar should be installed according to the problems that high shutdown black voltage,low rectification efficiency,high air consumption,high power consumption of per ton aluminum,therefore total resistance of bus bar for single cell was decreased,the black voltage of shutdown,the reactive power loss and production cost is decreased.By installation of jumper bus bar,the black voltage of each cell can be decreased averagely by 79.3 mV,it can save¥319RMB of each cell per day.
作者 钟代勇 杨福全 刘强 陈大松 汤其吉 官寿荣 黄国宏 ZHONG Dai-yong;YANG Fu-quan;LIU Qiang;CHEN Da-song;TANG Qi-ji;GUAN Shou-rong;HUANG Guo-hong(Yunnan Aluminum Haixin Aluminum Industry Co.,Ltd.,Zhaotong,Yunnan 657000,China)
出处 《云南冶金》 2022年第1期169-175,共7页 Yunnan Metallurgy
关键词 铝电解 停槽 黑电压 无功空耗 跨接母线 生产成本 aluminum electrolysis shutdown of electrolytic cell black voltage reactive power loss jumper bus bar production cost