摘要
某核电厂主蒸汽旁路调节阀异常动作导致阀门故障率高问题长期存在。结合调节阀动作原理对该问题进行根本原因分析,提出改进方案。实施该改进方案后,主蒸汽旁路调节阀异常动作问题得以解决。
The abnormal action of main steam bypass control valve in a nuclear power plant leads to high valve failure rate,which has existed for a long time.Based on the principle of regulating valve action,the root cause of the problem is analyzed,and the improvement scheme is put forward.After the implementation of the improvement scheme,the abnormal action of the main steam bypass regulating valve can be solved.
作者
曾博文
张利冰
ZENG Bowen;ZHANG Libin(CNNP Nuclear Power Operations Management Co.,Ltd.,Jiaxing 314300,China)
出处
《电工技术》
2022年第2期29-31,共3页
Electric Engineering
关键词
主蒸汽
调节阀
频繁动作
泄漏
main steam
regulating valve
frequent action
leak