摘要
分析了医院UPS蓄电池的常见问题,提出了加强常规巡检、监测蓄电池内阻、使用测温纸和红外热像仪检测蓄电池温度、从温度指标判断蓄电池是否存在异常等应对措施,旨在及时发现及处理蓄电池的异常。
It analyzes the common malfunctions of UPS batteries in hospitals,and proposes countermeasures such as strengthening routine inspections,monitoring the internal resistance,using temperature measuring paper and infrared thermal imaging cameras to detect the battery temperature,and determine whether the batteries are abnormal from the temperature indicators in order to deal with it in time.
出处
《中国医院建筑与装备》
2022年第2期79-81,共3页
Chinese Hospital Architecture & Equipment
关键词
蓄电池
UPS
医院后勤管理
Battery
UPS
Logistics management of hospital