期刊文献+

硬化混凝土中酸溶性氯离子含量检测方法对比研究

Comparative Study on Detection Methods of Acid-Soluble Chloride Ion Content in Hardened Concrete
下载PDF
导出
摘要 通过用全自动电位仪滴定仪法、离子色谱法测试硬化混凝土中酸溶性氯离子,对两种方法进行比较分析,发现两种方法准确度和精密度高,两种检测方法和国标法测定的结果无显著性。离子色谱法的结果较好,检出限低,相对误差和相对偏差分别为0.005%、2.25%,低于全自动电位仪滴定法0.0019%、5.39%,加标回收率为101%~105%,两种方法应用到硬化混凝土氯离子的分析,满足检验检测分析的需要。 By using automatic potentiometer titrator method and ion chromatography to test acid-soluble chloride ion in hardened concrete,the two methods are compared and analyzed.It is found that the two methods have high accuracy and precision,and the results of the two detection methods and the national standard method were not significant.The results of ion chromatography are good,the detection limit is low.The relative error and relative deviation were 0.005%and 2.25%,respectively,which were lower than 0.0019%and 5.39%of the automatic potentiometer titration method.The recovery rate of standard addition was 101%~105%.The two methods are applied to the analysis of chloride ions in hardened concrete to meet the needs of inspection and analysis.
作者 马涛 Ma Tao(Shanghai Zhongcai Engineering Testing Co.,Ltd.,Shanghai 201203,China)
出处 《建筑与装饰》 2022年第4期190-192,共3页 Construction & Decoration
关键词 硬化混凝土 酸溶性氯离子 方法比对 hardened concrete acid-soluble chloride ion method comparison
  • 相关文献

参考文献3

二级参考文献16

  • 1陈忠明,李家胜.电位滴定法测定啤酒中氯离子含量[J].食品与发酵工业,1993,19(4):48-50. 被引量:6
  • 2魏洽,颜流水.自动电位滴定法测定啤酒中氯离子含量[J].南昌航空工业学院学报,1996,10(2):53-57. 被引量:1
  • 3[3]农业部全国土壤肥料总站.氯离子的测定(硝酸银滴定法),土壤农业化学分析方法[M].北京:中国农业出版社,1999.92-93.
  • 4ZHANG Yi, JIN Wei-liang. Distribution of chloride ac- cumulation in marine tidal zone along altitude [J]. Mate- rial Journal, 2011, 108(5) :467 - 475.
  • 5FAJARDO G, ESCADEILLAS G, ARLIGUIE G. Elec- trochemical chloride extraction (ECE) from steel-rein- forced concrete specimens contaminated by "artificial" sea-water [J]. Corrosion Science, 2006, 48 : 110 - 125.
  • 6MIRANDA J M, GONZGALEZ J A, COBO A, et al . Several question about electrochemical rehabilitation methods for reinforced concrete structures [J]. Corro- sion Science, 2006 ,48:2172 - 2188.
  • 7SAWADA S, KUBO J, PAGE C L, et al. Electrochem- ical injection of organic corrosion inhibitors into carbona- ted cementitious materials: Part 1. Effects on pore solu- tion chemistry [J]. Corrosion Science, 2007, 49 (3): 1186 - 1204.
  • 8SAWADA S, PAGE C L, PAGE M M . Electrochemi- cal injection of organic corrosion inhibitors into concrete [J]. Corrosion Science, 2005, 47 (8): 2063-2078.
  • 9KUBO J, SAWADA S, PAGE C L, et al. Electrochem- ical inhibitor injection for control of reinforcement corro- sion in carbonated concrete[J]. Materials and Corrosion, 2008, 59 (2): 107-114.
  • 10ASTM G61-86. The standard test method for conduc- :ing cyclic potentiodynamic polarization measurements for localised corrosion susceptibility of iron-, nickel-, or :obaltbased alloys [S]. West Conshohocken, PA:ASTM Intemational, 2003.

共引文献90