期刊文献+

高温长距离供热系统腐蚀结垢控制研究

Study on corrosion and scaling control of high temperature and long distance heating system
下载PDF
导出
摘要 在2018-2019年采暖季供热期间,发现大温差供热管网换热设备腐蚀结垢情况严重。经过检验和分析,垢主要来源于循环水结垢和腐蚀产物的沉积;腐蚀产物来源于管道内壁腐蚀。同时热网循环水氯离子含量过高,板式换热器不锈钢发生了点蚀。研究试验结果表明:采用阻垢剂、缓蚀剂、调节pH和控制氯离子含量等措施可以保证循环水不结垢,也可以控制管道内壁腐蚀及不锈钢点蚀。在实际应用中,热网循环水浊度和悬浮物明显下降并合格,换热设备腐蚀结垢速率显著降低,保证了供热系统的安全经济运行。 During the heating season from 2018 to 2019,it was found that the corrosion and scaling of heat exchange equipment in large temperature difference heating pipe network was serious.Through inspection and analysis,the scale mainly came from circulating water scaling and corrosion product deposition which came from the corrosion of the inside of the pipeline.At the same time,due to the high chloride ion content in the circulating water of heat supply network,the stainless steel of plate heat exchanger has pitting corrosion.The test results showed that using scale inhibitor,corrosion inhibitor,adjusting pH and controlling chloride ion content could not only ensure the circulating water not to scale,but also control the corrosion of inside of pipeline and pitting corrosion of stainless steel.In practical application,the turbidity and suspended solids of circulating water in heat supply network were significantly reduced and qualified.the corrosion and scaling rate of heat exchange equipment is significantly reduced,which ensured the safe and economic operation of heating system.
作者 李海洋 阴峰 邓宇强 温凯 郭焱 Li Haiyang;Yin Feng;Deng Yuqiang;Wen Kai;Guo Yan(Huadian Electric Power Research Institute Co.,Ltd.;Guoneng Ningxia heating Co.,Ltd.;Xi’an Thermal Power Research Institute Co.,LTD)
出处 《区域供热》 2022年第1期1-5,18,共6页 District Heating
关键词 换热设备 腐蚀结垢 点蚀 循环水 氯离子含量 heat exchange equipment corrosion and scaling pitting corrosion the circulating water chloride ion content
  • 相关文献

参考文献5

二级参考文献43

共引文献97

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部