From laboratory to on-site operation:Reevaluation of empirically based electric water chiller models 被引量:2

原文传递
导出
摘要 Chiller model is a key factor to building energy simulation and chiller performance prediction.With spread of new types of electric water chillers that have higher performance and wider operating range,new challenges have been faced by building energy simulation tools and their chiller models.This work takes a new type of electric water chiller as a case study and reevaluates eight typical empirically based models for predicting the energy performance of electric water chiller to verify whether they are suitable for the new type of chiller,using both laboratory test data from chiller manufacturer and online monitoring data from on-site operation of a central cooling plant with chillers of the same type.The prediction ability of the chiller models(including model prediction accuracy and generation ability)in laboratory test and on-site operation situations are examined.The results show that the existing models can well describe the chiller performance in the laboratory test situation but perform poorly in the on-site operation situation.As the best two models in the laboratory dataset,the overall prediction errors of DOE-2 and GN model increase more than 250%and 75%respectively in the field dataset.The big discrepancy of model prediction accuracy in the two situations is mainly due to the differences of evaporator and condenser water flow rates between the laboratory and on-site operation datasets,which indicates the limitations of the empirical chiller models and implies further research in future in order to improve the suitability and reliability of chiller model.
出处 《Building Simulation》 SCIE EI CSCD 2022年第2期213-232,共20页 建筑模拟(英文)
基金 supported by the State Key Laboratory of Air-Conditioning Equipment and System Energy Conservation(No.ACSKL2019KT13) National Natural Science Foundation of China(No.51608297 and No.51678024) Scientific Research Project of Beijing Municipal Education Commission(No.KM201910016009 and No.KZ202110016022) Beijing Advanced Innovation Center for Future Urban Design(No.UDC2019011121) Fundamental Research Funds for Beijing University of Civil Engineering and Architecture(No.XI8301).
  • 相关文献

参考文献5

二级参考文献35

  • 1王松佳,陈敏,陈立萍.线性统计模型:线性回归与方差分析[M].北京:高等教育出版社,1999.
  • 2国务院.中华人民共和国国务院令第531号公共机构节能条例[S].2008.
  • 3中国建筑科学研究院.IGJ/T177-2009公共建筑节能检测标准[S].北京:中国建筑工业出版社,2010.
  • 4ASHRAE. ASHRAE Guideline 14-2002 Measurement of Energy and Demand Savings[ S]. 2002.
  • 5Swider DJ, Browne MW, Bansal PK, et al. Modelling of vapour- compression liquid chillers with neural networks [J]. Applied Thermal Engineering,2001,21 (3) :311 - 329.
  • 6Agami T. Reddy, Klaus Kaae Andersen. An evaluation of classical steady-state off-line linear parameter estimation methods applied to chiller performance data [ J ]. HVAC&R Research, 2002,8 (1):101 -124.
  • 7Hydemam M, Gillespie KL. Tools and techniques to calibrate electric chiller component models [ J ]. ASHRAE Transactions, 2002,108(1) :733 -741.
  • 8Gordont JM, Kimchoon NG, Predictive and diagnostic aspects of a universal thermodynamic model for chillers [ J ]. International Journal of Heat and Mass Transfer, 1995,38(5 ) :807 - 818.
  • 9Hydeman M, Webb N, Sreedharan P, et al. Development and testing of a reformulated regression-based electric chiller model [ J ]. ASHRAE Transactions, 2002,108 ( 2 ) : 1118 - 1127.
  • 10Sreedharan P, Haves P. Comparison of chiller models for use in model-based fault detection [ C ]//Proceedings of International Conference for Enhancing Building Operations,2001.

共引文献37

同被引文献11

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部