期刊文献+

Impacts of uneven surface heating of an ideal street canyon on airflows and indoor ventilation:Numerical study using OpenFOAM coupled with EnergyPlus

原文传递
导出
摘要 In the daytime,building facades and ground surfaces are heated by solar radiation,and the resulting buoyancy can change the flow field inside street canyons.In this study,the impacts of uneven and time-varying heating of surfaces inside an ideal urban street canyon(aspect ratio=1)on single-sided indoor natural ventilation are analyzed.This work introduces a methodology for a numerical approach based on the coupling between a computational fluid dynamics(CFD)model and an energy balance model.First,EnergyPlus is employed to calculate the time-varying and uneven surface heating.Simulations are performed at four typical study times(05:00,09:00,15:00,20:00)during a hot summer day(July 15)in Wuhan,China.Second,the surface temperature results are transferred to OpenFOAM for CFD simulation.Two inlet wind velocities(U_(ref))are investigated.The results show that for a relatively strong ambient wind(U_(ref)=3 m/s),the buoyancy caused by surface heating does not significantly change the airflow structures and indoor ventilation compared with those in the isothermal case.However,for a weak ambient wind(U_(ref)=0.5 m/s),the airflow structures inside the street canyon vary with the time of day.Moreover,the average air exchange rate(ACH)differs by-25.0% to 15.9%compared with that in the isothermal case,and the ACH of a single room increases by up to 2710%.The results indicate that the surface-heating-induced buoyancy is nonnegligible and should be carefully investigated,especially for weak ambient winds.
出处 《Building Simulation》 SCIE EI CSCD 2022年第2期265-280,共16页 建筑模拟(英文)
基金 supported by the National Natural Science Foundation of China(No.51778251).
  • 相关文献

参考文献1

二级参考文献9

  • 1Huang H, Akustsu Y, Arai M, et al. An air quality model in an urban street canyon: validation and sensitivity analysis [J]. Atmos Environ,2000, 34:687 - 696.
  • 2Kastner-Klein P, Plate E J. Wind-tunnel study of concentration fields in street canyon [J]. Atmos Environ, 1999, 33: 3973- 3979.
  • 3Gerdes F, Olivari. Analysis of pollutant dispersion in an urban street canyon [J]. Journal of Wind Engineering and Industrial Aerodynamics,1999, 82: 105- 124.
  • 4Huang Zhen, Wang Jiasong, Xie Zheng, et al. Numerical prediction of traffic-related air pollution in urban street canyons of asymmetrical layout[A]. Proceedings of International Conference on Energy and the Environment [ C ]. Shanghai: University of Shanghai for Science and Technology, 2003. 1266- 1271.
  • 5Meroney R N, Michel P, Stilianos R, et al. Study of line source characteristics for 2-D physical modelling of pollutant dispersion in street canyons [J]. Journal of Wind Engineering and Industrial Aerodynamics,1996, 62: 37- 56.
  • 6周洪昌,吴晓琰.街道峡谷湍流流动的风洞试验与数值计算[J].空气动力学学报,1998,16(4):411-418. 被引量:18
  • 7张化天,谢绍东,张远航.城市街道峡谷内机动车排放污染物的扩散规律[J].环境科学研究,2002,15(1):51-54. 被引量:7
  • 8王嘉松,黄震.城市高架道路对局地大气环境影响的数值模拟研究[J].上海环境科学,2002,21(3):132-135. 被引量:12
  • 9王嘉松,黄震.应用不同湍流模式预测城市街道峡谷的大气环境[J].上海交通大学学报,2002,36(10):1496-1499. 被引量:29