期刊文献+

火电厂循环水系统水损失分析与改进措施 被引量:4

Analysis of Water Loss of Circulating Water System in Thermal Power Plants and Improvement Measures
下载PDF
导出
摘要 分析了火电厂高浓缩倍率循环水对冷却设备安全状态的影响、循环水节水与循环水设备安全的影响因素,指出了冷却设备的多发缺陷,提出了提高循环水设备安全性的改进建议。从循环水的再利用角度,提出全膜法技术在循环水清洁工程中的应用方案。 The influence of circulating water with high concentration rate on the safety state of cooling equipment in thermal power plants and the influence factors of circulating water conservation and circulating water equipment safety are analyzed,the multiple defects of cooling equipment are pointed out,the suggestions to improve the safety of circulating water equipment are put forward.The scheme of applying the integrated membrane technology to circulating water cleaning projects is put forward from the perspec⁃tive of recycling circulating water.
作者 姚新明 赵永国 张新国 焦俊杰 YAO Xinming;ZHAO Yongguo;ZHANG Xinguo;JIAO Junjie(China Energy Heze Power Generation Co.,Ltd.,Heze 274032,China)
出处 《山东电力高等专科学校学报》 2022年第1期47-50,共4页 Journal of Shandong Electric Power College
关键词 循环水系统 化学腐蚀 全膜法技术 circulating water system chemical corrosion integrated membrane technology