摘要
研究了废催化剂中铑、铱、钌含量的分析方法。采用镍锍试金富集,镍扣用铝共熔,然后用盐酸(1+1)分离镍和铝,沉淀用高压消解罐溶解,电感耦合等离子原子发射光谱法测定铑、铱、钌。实验结果表明,加入6 g铝镍扣在900℃的马弗炉中共熔2 h,镍扣能在盐酸(1+1)中2 h以内溶解完全,方法相对标准偏差RSD(n=7)在1.2%~7.7%,铑、铱、钌的加标回收率在96.2%~100%,方法准确、可靠,可满足交易及科研需求。
The analytical methods of rhodium,iridium and ruthenium in spent catalysts are studied.The nickel sulphide fire-assay is used for enrichment.The nickel button is melted together with aluminum,which is dissolved by hydrochloric acid solution(1+1),and the precipitate is dissolved in a high-pressure digestion tank.Inductively coupled plasma atomic emission spectrometry is used to determine rhodium,iridium and ruthenium in spent catalysts.The test results show that when 6 g aluminum and nickel buttons are co-melting in a muffle furnace at 900℃for 2 hours,the nickel buttons can be completely dissolved in hydrochloric acid(1+1)within 2 hours.The relative standard deviation RSD(n=7)of the method was between 1.2%and 7.7%.The recoveries of rhodium,iridium,and ruthenium were between 96.2%and 100%indicating that the method is accurate and reliable,and can meet the needs of trading and scientific research.
作者
熊方祥
杨炳红
符招弟
郭桓煜
XIONG Fangxiang;YANG Binghong;FU Zhaodi;GUO Huanyu(Changsha Mining and Metallurgy Institute Testing Technology Co.,Ltd.,Changsha,Hunan 410012,China)
出处
《中国无机分析化学》
CAS
北大核心
2022年第2期72-75,共4页
Chinese Journal of Inorganic Analytical Chemistry
关键词
镍锍试金法
铝共熔
电感耦合等离子体发射光谱法
废催化剂
铑
铱
钌
nickel sulphide fire-assay
aluminum eutectic
inductively coupled plasma optical emission spectrometry
spent catalysts
rhodium
iridium
ruthenium