期刊文献+

核电厂厚壁高密度聚乙烯管道热熔接头的相控阵超声检测 被引量:3

Phased array ultrasonic testing for hot melt joint of thick wall high density polyethylene pipe in nuclear power plant
下载PDF
导出
摘要 分析了核电厂厚壁高密度聚乙烯管道热熔接头体积检查的主要难点。基于对高密度聚乙烯材料的声学性能和相控阵超声声场的建模分析,定制了自聚焦相控阵超声探头和特殊结构相控阵水楔块,有效解决了壁厚大于90 mm的高密度聚乙烯热熔接头的超声检测问题。通过对国内某核电站厂用水系统32英寸高密度聚乙烯管道的现场检测,验证了该检测技术的有效性。 The main difficulties of the volume inspection for thick wall HDPE pipe hot melt joint were analyzed. Based on the acoustic properties of HDPE material and the acoustic field modeling analysis of phased array ultrasonic, self-focusing phased array ultrasonic probe and special structure water wedge are customized, which effectively solves the ultrasonic detection problem of HDPE hot melt joint with wall thickness greater than 90 mm. The effectiveness of the detection technology was verified by the field inspection of 32 inch HDPE pipeline of the water system in a nuclear power plant.
作者 周路生 黄骄 吴双 邱晓东 王立仁 ZHOU Lusheng;HUANG Jiao;WU Shuang;QIU Xiaodong;WANG Liren(State Nuclear Power Plant Service Company,Shanghai 200233,China;Shanghai Nuclear Engineering Research&-Design Institute Co.,Ltd.,Shanghai 200233,China)
出处 《无损检测》 CAS 2022年第1期10-15,共6页 Nondestructive Testing
基金 核电厂结构健康检测分析与评价先进技术研究项目(2018ZX06002008)。
关键词 核电厂 高密度聚乙烯 热熔接头 相控阵超声 nuclear power plant HDPE hot melt joint phased array ultrasonic
  • 相关文献

参考文献3

二级参考文献10

共引文献26

同被引文献78

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部