摘要
文章采用数值仿真结合实验的研究方式,对自调节的管束除雾器装置进行数值计算和现场实验,分析了当总烟气量变化时,自调节装置对管束除雾器所起的作用。结果表明:当总烟气量降低时,自调节装置可以自发关闭一部分管束,让其余管束除雾器在设计风速下正常工作。
In this paper, by means of numerical simulation and experiment, numerical calculation and field experiment were carried out for the self-regulating device on tube bundle demister, so as to analyze the effect of self-regulating device on tube bundle demister when the total amount of smoke changes. According to the results, the self-regulating device can automatically close a part of the tube bundle when the total amount of smoke decreases, and thus enables the remaining tube bundle demister work normally under the designed wind speed.
作者
尹成
任凯
任轩
YIN Cheng;REN Kai;REN Xuan(Xi'an Xikuang Environmental Protection Co.,Ltd.,Xi'an 710075,China)
出处
《中国环保产业》
2022年第1期69-72,共4页
China Environmental Protection Industry
关键词
管束除雾器
自调节
数值仿真
tube bundle demister
self-regulating
numerical simulation