期刊文献+

基于STM32的智能药箱设计 被引量:1

Design of Smart Medicine Box Based on STM32
下载PDF
导出
摘要 近年来,随着老龄人口的不断上涨,老年人按时吃药难的问题逐渐暴露出来。针对老年人容易忘记吃药的问题,我们设计了一个以STM32为主控芯片辅助老年人吃药的智能药箱。该装置采用OpenMV4 H7摄像头进行人脸识别,使用有源蜂鸣器作为提醒老年人吃药的发声装置,配有心率血氧模块对老年人进行身体健康检测,同时还具备无线通信的功能,让亲属能实时查看老年人的状况。该装置功能齐全,操作简单,能够有效地提醒老年人按时吃药。
作者 王浩 钟国锋 WANG Hao;ZHONG Guofeng
出处 《自动化应用》 2021年第12期71-74,共4页 Automation Application
  • 相关文献

参考文献3

二级参考文献28

  • 1杜鹏,李龙.新时代中国人口老龄化长期趋势预测[J].中国人民大学学报,2021,35(1):96-109. 被引量:195
  • 2李建新.国际比较中的中国人口老龄化变动特征[J].学海,2005(6):15-19. 被引量:24
  • 3Nijboer J A, Dorlas J C, Mahieu H F. Photoelectric plethysmography-some fundamental aspects of the reflection and transmis sion methods[J]. Clinical Physics and Physiological Measurement, 1981, 2: 205--215.
  • 4Bernardi L. , Radaelli A. , Solda' P L. Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves[J].Clinic Science, 1996, 90:345-355.
  • 5Anders Johansson, Per Ake Oberg, Gunnar Sedin. Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique[J].Journal of Clinical Moni toring and Computing, 1999,15 : 461-467.
  • 6Nilsson L, Johansson A, Kalman S. Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique[J]. Journal of Clinical Monitoring and Computing, 2000,16: 309-315.
  • 7Nilsson L, Johansson A, Kalman S. Respiration can be moni tored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory mode[J].Acta Anaesthesiologiea Scandinavica, 2005,49(8) : 1157 - 1162.
  • 8Nilsson L, Goscinski T, Johansson A. Age and gender do not influence the ability to detect respiration by photoplethysmography[J].Journal of Clinical Monitoring and Computing, 2006, 20(6) :431--436.
  • 9Clifton D, Douglas J G, Addison P S. Measurement of respiratory rate from the photoplethysmogram in chest clinic patients [J]. Journal of Clinical Monitoring and Computing, 2007, 21 (1) : 55--61.
  • 10Lin Y D, Liu W T, Tsai C C. Coherence Analysis between Respiration and PPG Signal by Bivariate AR Model [J]. Engineering and Technology, 2009, 53 : 847--852.

共引文献126