期刊文献+

X荧光压片法测定80%钒铁中V、Si、Al、P多元素含量

Determination of V,Si,Al and P Contents in 80%V Ferrovanadium by X-Ray Fluorescence Spectrometer and Powder-Tabletting Method
下载PDF
导出
摘要 由于无80%钒铁的标准样品,因此我们采用钒铁生产厂家分析过的不同含量的样品,自配制不同V、Si、Al、P含量梯度的样品,通过化学法及ICP等离子光谱仪和钒铁生产厂家做对比实验,最后定值,建立X荧光80%钒铁V、Si.Al、P分析曲线,采取化学法与仪器法紧密结合,为炼钢生产提供准确的数据,监督80%钒铁质量,更好地指导炼钢生产。本方法精密度好,准确度高,而且分析速度快,分析过程简单易于操作。 There are no standard samples of 80%V ferrovanadium in our physical and chemical analysis laboratory,therefore,the ferrovanadium samples with gradient contents of V,Si,Al and P are chosen from ferrovanadium samples with known components from ferrovanadium manufactures and retested by a chemical method and a inductively coupled plasma(ICP)spectrometer method,the results from the chemical method and the ICP method are compared with the components from manufactures and then confirmed,a X-ray fluorescence analysis curve of V,Si,Al and P in 80%V is set up.In this way,the chemical method and the ICP method are cooperated closely to provide accurate data for steelmaking production,supervise the quality of 80%V ferrovanadium and better guide steelmaking production.The ICP method has good precision,high accuracy and fast analysis speed and is simple and easy to operate.
作者 邓雯锦 吴丽萍 张燕 龚宇虓 陈再生 Deng Wenjin;Wu Liping;Zhang Yan;Gong Yuxiao;Chen Zaisheng(Manufacture ManagementDepartment,Shougang ShuichengIron&Steel(Group)Co.,Ltd.,Liupanshui 553028,Guizhou,China)
出处 《水钢科技》 2022年第1期11-15,共5页 Shuigang Science & Technology
关键词 X荧光 压片法 80%钒铁 X-ray fluorescence tabilleting method 80%V ferrovanadium