北方核电厂机组夏季出力特性及优化建议 被引量:1

Analysis on Output Characteristics of a North Nuclear Power Unit in Summer
下载PDF
导出
摘要 针对北方核电厂夏季工况时机组出力偏低问题,通过综合对比设计参数、汽轮机选型、机组出力曲线和机组发电量等因素,对北方核电厂夏季机组出力的特性进行分析。CPR1000堆型核电厂机组出力随海水温度的变化而变化,但南北方机组由于低压缸配置不同、排汽面积不同,北方机组在夏季工况下,机组出力随海水温度的变化趋势更加明显。海水温度变化1℃,机组出力变化可达到8~10 MW,可能出现在夏季短时间内机组出力小于南方机组的情况。这是其机组出力自然特性决定的,属于正常现象。在此基础上,针对性提出了小幅提升一回路热功率和循环水泵变频改造的方案,以提高北方核电机组夏季出力能力。 Aiming at the problem of low generating power of a northern nuclear power plant in summer,by comparing the design parameters,steam turbine selection,unit output curve and unit generating capacity comprehensively,the characteristics of northern unit output in the north in summer was analyzed.By comparing the output characteristics of the same reactor type nuclear power units in the South and North,it is found that the unit output of CPR1000 reactor type nuclear power plant changes with the temperature of seawater.However,due to the different low-pressure cylinder configuration and steam exhaust area of the South and North units,the change trend of unit output with seawater temperature is more obvious under the working condition of the North unit in summer,the temperature of seawater changes by 1℃,the output variation of the unit can reach 8-10 MW,which may be lower than that of the unit in the South in a short period of time。But this is normal because of the output characteristics of the unit in North.On this basis,to improve the summer output of North nuclear power unit,a small increase of primary circuit thermal power and frequency conversion transformation of circulating water pump were proposed.
作者 凌学会 LING Xuehui(Liaoning Hongyanhe Nuclear Power Co.,Ltd.,Dalian 116000,Liaoning,China)
出处 《能源研究与管理》 2022年第1期120-125,共6页 Energy Research and Management
关键词 北方核电厂 机组出力 夏季 汽轮机 海水温度 northern nuclear power plant unit output summer steam turbine sea water temperature
  • 相关文献

参考文献14

二级参考文献43

共引文献33

同被引文献15

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部