摘要
目的观察质量控制图在重症医学科(ICU)“三管”感染管理中应用。方法收集2012年1月-2020年12月医院ICU病房每年的“三管”监测数据,分析并建立“三管”感染质量控制图。结果ICU病房每年尿管插管总时长1173~3642 d,每年导尿管相关性泌尿道感染(CAUTI)发生率为0‰~3.17‰;每年中心静脉插管总时长905~2854 d,每年中心静脉导管相关性血流感染(CLABSI)发生率为0.64‰~5.30‰;每年呼吸机使用总时长739~2757 d,每年呼吸机相关性肺炎(VAP)发生率为2.38‰~6.98‰。质量控制图显示每年CAUTI、CLABSI、VAP发生率数据点均落在控制限内,处于可控状态。结论质量控制图可直观监控ICU“三管”感染发生情况。
Objective To observe the application of quality control chart(QCC)in control in ICU.Methods The annual 3-catheter monitoring data in ICU during January 2012 and December 2020 were analyzed,followed by establishing QCC of 3-catheter infection.Results The overall time of urinary catheter,central venous intubation,and ventilator per year was 1173-3642 d,905-2854 d,and 739-2757 d,respectively.The annual incidence of catheter-related urinary tract infection(CAUTI),central venous catheter-related bloodstream infection(CLABSI),and ventilator-associated pneumonia(VAP)was 0‰-3.17‰,0.64‰-5.30‰,and 2.38‰-6.98‰,respectively.QCC showed that annual incidence of CAUTI,CLABSI and VAP was within control limit.Conclusion QCC can monitor intuitively the occurrence of 3-catheter infection in ICU.
作者
李建坤
李瑞萍
杨明珊
黎焯基
LI Jian-kun;LI Rui-ping;YANG Ming-shan;LI Zhuo-ji(Second Affiliated Hospital of Guangdong Medical University,Zhanjiang 524000,China)
出处
《广东医科大学学报》
2022年第1期58-61,共4页
Journal of Guangdong Medical University
关键词
质量控制图
重症医学科
导管感染
quality control chart
intensive care unit
catheter infection