期刊文献+

Relationship between corneal biomechanical parameters and corneal sublayer thickness measured by Corvis ST and UHR-OCT in keratoconus and normal eyes 被引量:3

原文传递
导出
摘要 Background:To explore the relationship between corneal biomechanical parameters and corneal sublayer thickness using corneal visualization Scheimpflug technology(Corvis ST)and ultrahigh-resolution optical coherence tomography(UHR-OCT)in clinical and suspected keratoconus and normal eyes.Methods:Cross-sectional prospective study.A total of 94 eyes of 70 participants were recruited.Twenty five eyes of 19 keratoconus patients,52 eyes of 34 patients showing high risk of developing keratoconus according to the Belin/Ambrosio Enhanced Ectasia Display,and each eye of 17 normal subjects were enrolled.All participants underwent Corvis ST,Pentacam,and UHR-OCT examinations at the same time.Stiffness parameter A1(SP-A1),deformation amplitude ratio(DA ratio),and other biomechanical parameters were recorded using Corvis ST.The vertical and horizontal thickness profiles of central 3mm corneal epithelium,Bowman’s layer,and stroma as measured by the perpendicular distance between the neighboring interfaces were generated using UHR-OCT.The flat keratometry and steep keratometry were obtained using Pentacam.Analysis of correlation was applied to explore the association between variables.Results:Most of the biomechanical parameters and corneal sublayer thickness profiles showed statistical differences among three groups.A statistically significant linear relationship was noted between SP-A1 and DA ratio in all three groups.SP-A1 was found to be positively correlated with epithelial and Bowman’s layer thickness in the keratoconus(KC)group,and with stromal thickness in all three groups.In the normal and suspected keratoconus(SKC)groups,only stromal thickness was included in the stepwise linear regression to predict SP-A1,whereas in the KC group,steep keratometry and Bowman’s layer thickness were included.Conclusions:Significant and different correlations were noted between corneal stiffness and corneal sublayer thickness in different groups,indicating that corneal sublayers may play different roles in maintaining corneal biomechanical stability between keratoconus and normal eyes.
出处 《Eye and Vision》 SCIE CSCD 2021年第1期6-17,共12页 眼视光学杂志(英文)
基金 supported by Zhejiang Provincial Natural Science Foundation of China under Grant No.LY17H120005 Key Projects in Scientific Research Foundation of National Health Commission and Medical Science and Technology Program of Zhejiang Province,WKJ-ZJ-1930 Wenzhou Science and Technology Project of Social Development in Medicine and Health,ZY2020010.
  • 相关文献

同被引文献16

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部