期刊文献+

Assessing progression of keratoconus: novel tomographic determinants 被引量:10

原文传递
导出
摘要 Several methods have been described in the literature to both evaluate and document progression in keratoconus,but there is no consistent or clear definition of ectasia progression.The authors describe how modern corneal tomography,including both anterior and posterior elevation and pachymetric data can be used to screen for ectatic progression,and how software programs such as the Enhanced Reference Surface and the Belin-Ambrosio Enhanced Ectasia Display(BAD)can be employed to detect earlier changes.Additionally,in order to describe specific quantitative values that can be used as progression determinants,the normal noise measurement of the three parameters(corneal thickness at the thinnest point,anterior and posterior radius of curvature(ARC,PRC)taken from the 3.0 mm optical zone centered on the thinnest point),was assessed.These values were obtained by imaging five normal patients using three different technicians on three separate days.The 95%and 80%one-sided confidence intervals for all three parameters were surprisingly small(7.88/4.03μm for corneal thickness,0.024/0.012 mm for ARC,and 0.083/0.042 mm for PRC),suggesting that they may perform well as progression determinants.
出处 《Eye and Vision》 SCIE 2016年第1期49-57,共9页 眼视光学杂志(英文)