期刊文献+

Optimization and Configuration of Control Parameters to Enhance Small-signal Stability of Hybrid LCC-MMC HVDC System 被引量:6

原文传递
导出
摘要 This paper investigates the small-signal stability of the hybrid high-voltage direct current(HVDC)transmission system.The system is composed of line commutated converter(LCC)as rectifier and modular multi-level converter(MMC)as inverter under weak AC grid condition.Firstly,the impact of short-circuit ratio(SCR)at inverter side on the system stability is investigated by eigen-analysis,and the key control parameters which have major impact on the dominant mode are identified by the participation factor and sensitivity analysis.Then,considering the quadratic index and damping ratio characteristic,an objective function for evaluating the system stability is developed,and an optimization and configuration method for control parameters is presented by the utilization of Monte Carlo method.The eigenvalue results and the electromagnetic transient(EMT)simulation results show that,with the optimized control parameters,the small-signal stability and the dynamic responses of the hybrid system are greatly improved,and the hybrid system can even operate under weak AC grid condition.
出处 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第1期213-221,共9页 现代电力系统与清洁能源学报(英文)
基金 This work was supported by the National Natural Science Foundation of China(No.51877077).
  • 相关文献

参考文献4

二级参考文献38

  • 1伍小杰,柴建云,王祥珩.变速恒频双馈风力发电系统交流励磁综述[J].电力系统自动化,2004,28(23):92-96. 被引量:110
  • 2邓集祥,赵丽丽.主导低频振荡模式二阶非线性相关作用的研究[J].中国电机工程学报,2005,25(7):75-80. 被引量:24
  • 3汤涌.电力系统强迫功率振荡的基础理论[J].电网技术,2006,30(10):29-33. 被引量:170
  • 4叶杭治.风力发电系统控制技术.2版.北京:机械工业出版社,2002.
  • 5PENA R, CLARE J C, ASHER G M. Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation, IEE Proceedings: Electric Power Applications, 1996, 143(3): 231 241.
  • 6PENA R, CLARE J C, ASHER G M. A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine. IEE Proceedings: Electric Power Applieations, 1996, 143(5): 380- 387.
  • 7NUNESMVA, LOPESJ AP, ZURN H H, et al. Influence of the variable-speed wind generators in transient stability margin of the conventional generators integrated in electrical grids. IEEE Trans on Energy Conversion, 2004, 19(4): 692- 701.
  • 8SORENSEN P, HANSEN A D, LUND T, et al. Reduced models of doubly fed induction generator system for wind turbine simulations. Wind Energy, 2006, 9(4) : 299 311.
  • 9DATAA R, RANGANATHAN V T. A method of tracking the peak power points for a variable speed wind energy conversion system. IEEE Trans on Energy Conversion, 2003, 18(1) : 163 -168.
  • 10PAPATHANASSIOU S A, PAPADOPOULOS M P. Statespace modelling and eigenvalue analysis of the slip energy recovery drive, lEE Proceedings: Electric Power Applications, 1997, 144(1): 27-36.