摘要 热熔型路面标线涂料用量巨大,其中重金属对环境造成很大污染.国内刚出台对其重金属等有害物质限量和检测方法的标准,但其中的重金属检测方法仍有改善的空间.该文建立了区别于标准的热熔型路面标线涂料重金属检测方法.首先采用正交试验,确定了热熔型路面标线涂料中硝酸、氢氟酸、过氧化氢相结合的消解体系;其次采用火焰原子吸收光谱法对铬、镉、铅、锑4种重金属进行检测,并优化燃助比(乙炔流量/空气流量)、燃烧头高度2个参数;最后采用氢化物发生原子吸收法对砷、汞进行检测,优化了酸质量分数、还原剂质量浓度、泵吸时间3个参数. 6种重金属元素的加标回收率为91.1%~109.2%,检出限分别为:0.011 mg/L、0.052 mg/L、0.025 mg/L、0.033 mg/L、0.272μg/L、0.223μg/L,结果表明该方法适用于热熔型路面标线涂料的有害物质检测. The amount of hot-melt pavement marking paint is huge,among which heavy metals cause great pollution to the environment.China has just issued the standards for the limits and detection methods of harmful substances such as heavy metals,but there is still room for improvement in the detection methods of heavy metals.The detection method of heavy metals in hot-melt pavement marking coating was established,which was different from the standard.First,the digestion system of nitric acid,hydrofluoric acid and hydrogen peroxide in hot-melt pavement marking coating was determined by orthogonal test.Second,four kinds of heavy metals(Cr,Cd,Pb,and Sb) were detected by FAAS.Two parameters of fuel assist ratio(acetylene flow/air flow) and combustion head height were optimized.Finally,hydride generation atomic absorption spectrometry was used to detect arsenic and mercury.Three parameters of acid concentration,reducing agent concentration and pumping time were optimized.The recoveries of six heavy metals were 91.1% to 109.2%,and the detection limits were 0.011 mg/L,0.052 mg/L,0.025 mg/L,0.033 mg/L,0.272 μg/L,and 0.223 μg/L,respectively.Results show that the method is suitable for the detection of harmful substances in hot-melt pavement marking paint.
作者 魏中华 徐鹏浩 杨宏旺 周炜 WEI Zhonghua;XU Penghao;YANG Hongwang;ZHOU Wei(Beijing Key Laboratory of Traffic Engineering,Faculty of Architecture,Civil and Transportation Engineering,Beijing University of Technology,Beijing 100124,China;Institute of Welding and Surface Engineering Technology,Faculty of Materials and Manufacturing,Beijing University of Technology,Beijing 100124,China)
出处 《北京工业大学学报》 CAS CSCD 北大核心 2022年第4期408-420,共13页 Journal of Beijing University of Technology
基金 国家自然科学基金资助项目(51608019)。
关键词 热熔型路面标线涂料 重金属 正交试验 原子吸收光谱法 检出限 加标回收率 hot melt pavement marking paint heavy metal orthogonal test atomic absorption spectrometry detection limit recovery rate of standard addition
  • 相关文献

参考文献11

二级参考文献87

共引文献45

同被引文献48

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部