摘要 以动作温度68℃的洒水喷头(T-ZSTX 15-68℃)进行静态动作温度试验,采用水、空气、导热油三种介质、两种升温方法分组进行洒水喷头静态动作温度试验,记录洒水喷头的静态动作温度。通过试验数据比对,分析加热介质和升温方法对洒水喷头静态动作温度试验结果的影响。经试验研究提出,不同的加热介质会对洒水喷头静态动作温度试验的结果产生影响。 The static action temperature test was carried out with the sprinkler head(T-ZSTX 15-68℃)with an action tem⁃perature of 68℃,and the sprinkler head static action temperature test was conducted by water,air,heat guide oil and two temperature rising methods.The influence of heating medium and heating method on static action temperature results is ana⁃lyzed by the test data.It is proposed that different heating media will affect the static action temperature test of the sprinkler nozzle.
作者 黄文佳 Huang Wen-jia(Nan’an Supervision Testing Institute of Quality&Metrology,Nan’an,Fujian 362300,China)
出处 《福建分析测试》 CAS 2022年第1期48-52,共5页 Fujian Analysis & Testing
关键词 洒水喷头 静态动作温度试验 水浴 空气浴 油浴 sprinkler static action temperature test water bath air bath oil bath
  • 相关文献

参考文献3

二级参考文献14

  • 1张村峰,霍然,李元洲.火灾中闭式喷头响应特性研究[J].中国工程科学,2005,7(11):55-59. 被引量:7
  • 2HUORan(霍然),YANGZhenhong(杨振宏),LIUJingxian(柳静献).Fire and explosion prevention and control engineering science (火灾爆炸预防控制工程学)[M].Beijing:ChinaMachine Press,2007:354-355.
  • 3ZHANGXuekui(张学魁).Building extinguishing equipments (建筑灭火设施)[M].Beijing: Publishing House of Chinese People's Public Security University, 2004: 128- 129.
  • 4GUPTA A K. Modeling the response of sprinklers in compartment fires [J]. Fire and Materials, 2001, 25 : 117 - 121.
  • 5EVANS D D. Calculating sprinkler actuation time in compartments[J]. Fire Safety Journal, 1985:147 - 156.
  • 6BUDNICK E K, EVANS D D, NELSON H E. Simplified fire growth calculations[ M]//COTE P E. Fire Protection Handbook. 19th ed. Quincy : National Fire Protection Association, lnc, 2003 : 97 - 107.
  • 7NELSON H E. FPETOOL: fire protection engineering tools for hazards estimations, NISTIR 4380[ R]. Gaithersburg: Building and Fire Research Laboratory, National Institute of Standards and Technology, 1990.
  • 8SHESTOPAL V O, GRUBITS S J. Computer program for an uninhibited smoke plume and associated computer software [ J ]. Fire Technology, 1993, 29(3) : 246-267.
  • 9EVANS D D, STROUP D W. Methods to calculate the response time of heat and smoke detectors installed below large unobstructed ceilings[ J ]. Fire Technology, 1986, 22:54-56.
  • 10CHOW W K. Performance of sprinkler in atrium[J]. Journal of Fire Science, 1996, 14:467-488.