立体光固化成型氧化锆固定桥精度及适合性研究 被引量:1

A study on the accuracy and fitness of zirconia fixed bridges fabricated by stereolithography
下载PDF
导出
摘要 目的:评价立体光固化成型氧化锆三单位固定桥精度和适合性。方法:制作立体光固化成型氧化锆固定桥和CAD/CA M切削固定桥各10个,通过3D偏差分析软件Geomagic Wrap对各组固定桥的精度及适合性进行检测,并对结果统计分析。结果:切削固定桥内表面,内部及边缘精度优于立体光固化成型氧化锆固定桥(P<0.05),两组固定桥外表面精度、边缘及内部适合性均无统计学差异(P>0.05)。结论:立体光固化成型氧化锆固定桥精度需要进一步提高,边缘及内部适合性符合临床要求。 Objective:To evaluate the accuracy and fitness of zirconia fixed bridges fabricated by stereolithography.Methods:Zirconia fixed bridges produced by stereolithography and CAD/CAM cutting respectively(n=10),the accuracy and fitness of the bridges were tested by 3D deviation analysis software-Geomagic Wrap,and the results were statistically analyzed.Results:The accuracy of inner surface,interior and edge of CAD/CAM cutting group was superior to that of stereolithography group(P<0.05),while there were no statistically significant differences in the measurement results of outer surface accuracy,edge and internal fitness(P>0.05).Conclusion:The accuracy of zirconia fixed bridges fabricated by stereolithography needs to be further improved,and the fitness of edge and internal of fixed bridegs meets clinical requirements.
作者 赵祯 代康 高勃 ZHAO Zhen;DAI Kang;GAO Bo(State Key Laboratory of Military Stomatology&National Clinical Research Center for Oral Diseases&Shaanxi Key Laboratory of Stomatology,Department of Prosthodontics,School of Stomatology,The Fourth Military Medical University,China,Xi'an 710032)
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2022年第2期204-208,共5页 Journal of Practical Stomatology
基金 国家口腔疾病临床医学研究中心临床课题重点项目(编号:LCA202011)。
关键词 立体光固化 CAD/CAM 氧化锆固定桥 精度 适合性 Stereolithography CAD/CAM Zirconia fixed bridge Accuracy Fitness
  • 相关文献

参考文献1

二级参考文献15

  • 1邬烈,骆小平.固定修复体适合性的研究方法[J].口腔颌面修复学杂志,2007,8(1):68-70. 被引量:18
  • 2于雪宁,杨晓东,宛莉娜.硅橡胶间隙印模检测金属烤瓷全冠适合性的可行性研究[J].中国医科大学学报,2007,36(5):569-571. 被引量:9
  • 3Kruth JP, Froyen L, Vaerenbergh .IV, et al. Selective laser mehing of iron-based powder[ J]. J Mater Process Tech, 2004, 149(s 1 -3) :616 -622.
  • 4Yap CY, Chua CK, Dong ZL, et al. Review of selective la- ser melting: Materials and applications [ J ]. Applied Physics Reviews, 2015, 2 ( 4 ) : 2071 - 2074.
  • 5Foster LV. Failed conventional bridge work from general dental practice: Clinical aspects and treatment needs of 142 cases[J]. BrDent J, 1990, 168(5):199-201.
  • 6Leong D, Chai J, Lautenschlager E, et al. Marginal fit of machine-milled titanium and cast titanium single crowns [J]. Int J Prosthodont, 1994, 7(5) :440 -447.
  • 7McLean JW, yon Fraunhofer JA. The estimation of cement fihn thickness by an in vivo technique[ J]. Br Dent J, 1971, 131(3) :107 - 111.
  • 8Mou SH, Chai T, Wang JS, et al. Influence of different convergence angles and tooth preparation heights on the in- ternal adaptation of Cerec crowns [ J ]. J Prosthet Dent, 2002, 87(3) :248 -255.
  • 9Materialsdevices, Council On Dental. Revised American Na- tional Standards Institute/American Dental Association Spec-ification No. 8 for Zinc Phosphate Cement[ J ]. J Am Assoc, 1978, 96(1) :121 -123.
  • 10Rahme HY, Tehini GE, Adib SM, et al. In. vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns[J]. J Contemp Dent Pract, 2008, 9(2) :25 -32.

共引文献6

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部