期刊文献+

Accuracy of shoulder joint injections with ultrasound guidance:Confirmed by magnetic resonance arthrography 被引量:1

下载PDF
导出
摘要 BACKGROUND Intra-articular glenohumeral joint injections are essential procedures for treating various shoulder disorders. Fluoroscopy-guided injections have been extensively used;however, they pose a risk of radiation exposure and are expensive and timeconsuming. Recently, it has been suggested that ultrasound-guided injections are accurate and cost effective procedures.AIM To evaluate the accuracy of ultrasound-guided glenohumeral injections using a posterior approach that is confirmed using magnetic resonance arthrography(MRA).METHODS The study included 179 shoulders of patients with recurrent anterior instability(150 patients;103 and 76 right and left shoulders, respectively;160 males and 19 females;average age = 20.5 years;age range: 14-63 years) who underwent MRA for preoperative diagnosis. They were injected with 12 m L lidocaine(1%) using the ultrasound-guided posterior approach and then underwent magnetic resonance imaging. Two shoulder surgeons, except for the injector, evaluated the transverse relaxation(T2)-weighted images of axial planes and classified the intraarticular condition of injected contrast into three groups based on one of the three following scenarios: no leakage, injection into the glenohumeral joint without leakage;minor leakage, practical intra-articular injection with some leakage outside the posterior rotator cuffs;and major leakage, inaccurate injection with mass leakage without any contrast into the joint. The inter-rater reliability between two assessors was also evaluated by calculating Cohen’s kappa coefficient. The learning curve was assessed regarding the inaccurate injection rate by analyzing Spearman’s rank correlation coefficient.RESULTS Of the 179 injections, 163 shoulders(91.0%) had no leakage, 10 shoulders(5.6%) had minor leakage, and six shoulders(3.4%) had major leakage. In total, 173 shoulders(96.6%) were intraarticularly injected;thus, we could detect anterior labrum and capsular pathologies. Regarding the inter-rater reliability, the kappa coefficient was 0.925, indicating consistency in the evaluations by both examiners. Regression analysis of the inaccurate injection rate for assessingtechnical learning showed a logarithmic curve with a downward trend(R;= 0.887, P < 0.001). Three(50%) of the six inaccurate injections classified into “major leakage” were observed in the first 30 injections, indicating that the accurate injection showed a leaning effect.CONCLUSION Ultrasound-guided intra-articular glenohumeral injections using a posterior approach had high accuracy;however, injection accuracy depends on clinical experience.
出处 《World Journal of Orthopedics》 2022年第3期259-266,共8页 世界骨科杂志(英文版)
  • 相关文献

参考文献2

共引文献1

同被引文献7

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部