摘要
基于痕量溶解氢含量测定的给水腐蚀氧化技术应用于府谷电厂600MW亚临界汽包炉。该机组采用AVT(O)给水处理和炉水超低磷酸盐处理工艺,通过对机组给水溶解氢含量的监督,并依据溶解氢含量进行水汽指标的调节,较好的完成了给水指标的优化。
The feed water corrosion oxidation technology based on the determination of trace dissolved hydrogen content was applied to 600MW Subcritical drum boiler of Fugu power plant. The unit adopts AVT(o) feedwater treatment and boiler water ultra-low phosphate treatment process. Through the supervision of dissolved hydrogen content in feedwater of the unit and the adjustment of water vapor index according to the dissolved hydrogen content, it is better The optimization of water supply index is completed..
作者
张久龙
吴利宁
刘忠
杨金生
ZHANG Jiu-long;WU Li-ning;LIU Zhong;YANG Jin-sheng(Deyuan Fugu Energy Co.,Ltd.Fugu 719400,China;Beijing Ruiaobo Science and Technology development Co.,Ltd.Beijing 100095,China)
出处
《全面腐蚀控制》
2022年第3期58-63,共6页
Total Corrosion Control
关键词
溶解氢
给水
优化
dissolved hydrogen
water supply
optimization