摘要
为了研究水喷淋系统和应急排烟系统对地铁站台火灾烟气特性的影响,建立了地铁站台火灾数值模型,应用FDS软件模拟计算了火源热释放速率为3MW时地铁站台火灾烟气温度、CO浓度、烟气能见度等火灾烟气主要参数的变化。结果表明:水喷淋系统可以降低地铁站台火灾烟气温度10℃左右,降低站台火灾CO浓度和提高烟气能见度的效果较差;增大应急排烟速度可以有效降低站台火灾烟气温度和CO浓度,提高烟气能见度。地铁消防自动喷水灭火系统设计和人员疏散方案设计可以考虑设置水喷淋系统与应急排烟系统,降低火灾烟气对人员疏散的危害。
A numerical model of subway platform fire is established to study the effects of sprinkler system and smoke extraction system on the smoke characteristics of subway platform fire.The FDS software is used to simulate and calculate the changes of main parameters of fire smoke,including smoke temperature,CO concentration and visibility,when the heat release rate of fire is 3MW.The results show that the sprinkler system can reduce the smoke temperature of subway platform fire by about 10 degrees,while its effect of reducing the CO concentration and improving the visibility is poor.The increase of the emergency smoke extraction speed can effectively reduce the smoke temperature and CO concentration and improve the visibility.The sprinkler system and emergency smoke exhaust system should be added in the subway fire-fighting system and evacuation scheme to reduce the harm caused by fire smoke.
作者
代长青
袁慧
王佳慧
DAI Changqing;YUAN Hui;WANG Jiahui(College of Civil Engineering,Anhui Jianzhu University,Hefei 230601,China;National-local joint Engineering Laboratory of building health monitoring and disaster prevention technology,Hefei 230601,China;School of Mathematics and Physics,Anhui Jianzhu University,Hefei 230601,China)
出处
《安徽建筑大学学报》
2022年第1期1-7,33,共8页
Journal of Anhui Jianzhu University
基金
安徽省教育厅高校自然科学基金项目(KJ2018JD01、KJ2021JD21)
安徽省科技厅自然科学基金项目(2108085ME159)
安徽省中央引导地方科技发展专项项目(2018080503B0020)
国家级大学生创新创业训练计划项目(202010878003)。
关键词
水喷淋系统
应急排烟系统
站台火灾
烟气参数
数值模拟
sprinkler system
emergency smoke extraction system
platform fire
smoke parameter
numerical simulation