摘要 目的:研究并分析光谱CT胸腹双下肢一站式血管扫描技术及临床应用优势。方法:将2020年4月~2021年4月由于双下肢动脉血栓入院诊断的81例患者纳入研究中,均采用Philps IQon Spectral CT进行胸腹双下肢一站式血管扫描法进行检查,针对图像质量、对比剂充盈情况、血管病变等进行评价。结论:一站式CTA血管扫描技术,适合于各种类型的血管硬化性闭塞病变,血栓引起的脉管炎检查,帮助临床医师掌握血栓的范围,并了解躯干各主要血管情况,是一项准确便捷的检查方法,颇具应用价值。 Objective:To study and analyze the advantages of spectral CT in one-stop angiography of thoracic and abdominal lower limbs and its clinical application.Methods:From April 2020 to April 2021,81 patients admitted to hospital for diagnosis of arterial thrombosis in lower limbs were included in this study.All patients were examined by Philps IQon Spectral CT with one-stop angiography of both lower limbs in chest and abdomen,and the image quality,filling of contrast agent and vascular lesions were evaluated.Conclusion:One-stop CTA vascular scanning technology is suitable for various types of vascular sclerosing occlusion lesions and vasculitis caused by thrombosis.It helps clinicians to master the scope of thrombosis and understand the main vessels of the trunk.It is an accurate and convenient examination method with great application value.
作者 林汉平 吴丹 Lin Hanping;Wu Dan(Department of Radiology,The Third Affiliated Hospital of Sun Yat-sen University,Guangzhou,Guangdong 510000)
出处 《现代医用影像学》 2022年第3期413-415,431,共4页 Modern Medical Imageology
关键词 光谱CT 胸腹双下肢一站式CTA影像成像技术 临床应用 spectral CT one-stop CTA imaging technology for chest and abdomen lower limbs clinical application
  • 相关文献

参考文献3

二级参考文献29

  • 1刘勇,张华.ALARA理论及CT低剂量应用研究进展[J].中国医学影像技术,2008,24(S1):17-20. 被引量:28
  • 2王锦良,李天然,钱根年,肖慧,李铭山.多层螺旋CT血管造影的影像分析[J].临床放射学杂志,2005,24(11):1026-1027. 被引量:24
  • 3Met R, Bipat S, Legemate DA, et al. Diagnostic performance of computed tomography angiography in peripheral arterial disease : a systematic review and meta-analysis. JAMA, 2009, 301 ( 4 ) : 415-424.
  • 4Fraioli F, Catalano C, Napoli A, et al. Low-dose muhidetector- row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA. Eur Radiol,2006, 16( 1 ) : 137-146.
  • 5Wintersperger B, Jakobs T, Herzog P, et al. Aorto-iliac muhidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol, 2005, 15(2) : 334-341.
  • 6Laswed T, Rizzo E, Guntern D, et al. Assessment of occlusive arterial disease of abdominal aorta and lower extremities arteries: value of multidetector CT angiography using an adaptive acquisition method. Eur Radiol, 2008, 18 (2) : 263-272.
  • 7Schemthaner R, Stadler A, Lomoschitz F, et al. Multi-detector CT angiography in the assessment of peripheral arterial occlusive disease: accuracy in detecting the severity, number, and length of stenoscs. Eur Radiol, 2008, 18(4) : 665-671.
  • 8Brenner D J, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med, 2007, 357 (22) :2277-2284.
  • 9Huda W, Scalzetti E, Levin G, et al. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology, 2000, 217 (2) :430-435.
  • 10Kalra MK, Maher MM, Blake MA, et al. Multidetector CT scanning of abdomen and pelvis: a study for optimization of automatic tube current modulation technique in 120 subjects (abstr). Radiological Society of North America Scientific Assembly and Annual Meeting Program. Oak Brook : Radioi Soci North Am, 2003:294.