期刊文献+

氢低温套管式换热器模拟及实验验证

Numerical simulation and experimental verification of hydrogen cryogenic tube-in-tube heat exchanger
下载PDF
导出
摘要 建立了考虑外管壁轴向导热与辐射漏热的套管式换热器数值模型,对搭建的预冷型液氢温区JT制冷机中套管式换热器出口温度进行模拟,结果表明:考虑外管壁的模型与实验结果更加吻合。利用该模型计算不同压比与流量情况下换热效率变化,流量由10 mg/s升高至30 mg/s,效率降低2.70%;压比由6升高至10,效率升高0.25%。 A tube-in-tube heat exchanger numerical model considering the axial conduction caused by outer wall and radiation heat leakage was established. The outlet temperature of the tube-in-tube heat exchanger in a precooled JT cryocooler working at liquid hydrogen temperature was simulated. The results show that the model considering outer wall is more consistent. The calculation of heat transfer efficiency with different pressure ratio and mass flow was carried out. When the mass flow increased from 10 mg/s to 30 mg/s,the efficiency was decreased by2. 70%. When the pressure ratio was increased from 6 to 10, the efficiency was increased by0. 25%.
作者 刘磊 申运伟 陈舒航 邱长煦 刘少帅 刘东立 甘智华 Liu Lei;Shen Yunwei;Chen Shuhang;Qiu Changxu;Liu Shaoshuai;Liu Dongli;Gan Zhihua(Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province,Institute of Refrigeration and Cryogenics,Zhejiang University,Hangzhou 310027,China;Cryogenics Center,Zhejiang University City College,Hangzhou 310015,China;Shanghai Institute of Technical Physics,Chinese Academy of Sciences,Shanghai 200083,China;Key Laboratory of 3D Micro/Nano Fabrication and Characterization of Zhejiang Province,School of Engineering,Westlake University,Hangzhou 310024,China)
出处 《低温工程》 CAS CSCD 北大核心 2022年第2期22-28,共7页 Cryogenics
基金 国家自然科学基金(51806231) 载人航天预先研究项目(010106) 上海科技创新基金(SAST2018-014)。
关键词 套管式换热器 模型计算 低温 实验 tube-in-tube heat exchanger numerical model cryogenic experiment verification
  • 相关文献

参考文献1

二级参考文献7

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部