某燃煤发电厂反渗透膜系统脱盐率下降案例分析 被引量:6

A Case Study on the Decline of the Desalination Rate in the Reverse Osmosis Membrane System of a Coal-fired Power Plant
下载PDF
导出
摘要 以某燃煤发电厂反渗透系统脱盐率异常下降事件为案例,研究了膜脱盐率下降原因,指出预处理系统杀菌剂加药量调整后,还原剂加药量没有相应的调整导致反渗透膜进水余氯超标,是导致膜被轻度氧化的直接原因;通过解剖实验,发现膜片有背压破坏现象,排查出清洗管路设置错误是导致清洗中分段产生背压的直接原因;提出了调整还原剂加药量、更改管路连接及设置膜片背压联锁值的解决措施,并成功恢复了反渗透系统的正常运行。 Taking an abnormal decrease of the desalination rate in the reverse osmosis system of a coal-fired power plant as an instance,the reasons for the decrease of the desalination rate in the membrane were analyzed.After adjusting the dosage of germicide in the pre-treatment system,the dosage of reducing agent was not adjusted accordingly,leading to the excess of residual chlorine in the influent,which caused the mild oxidation of the membrane directly;By anatomical tests,the membrane was damaged owing to the back-pressure,and it was found that the incorrect setting of the cleaning pipeline was the direct reason of back-pressure generation in the cleaning section;Several solutions including adjusting the dosage of reducing agent,changing the pipe connection and setting the interlock value of the diaphragm back pressure were proposed,in which the normal operation of the reverse osmosis system was restored successfully.
作者 冯向东 封立林 沈叔云 张雨婷 高凯楠 张林 FENG Xiangdong;FENG Lilin;SHEN Shuyun;ZHANG Yuting;GAO Kainan;ZHANG Lin(Zhejiang Energy Group R&D Co.,Ltd,311121;Engineering Research Center for New Industrial Water Resources of Zhejiang Province,311121;Zhejiang Zheneng Electric Power Co.,Ltd,310007;College of Chemical and Biological Engineering,Zhejiang University,310027,Hangzhou,China)
出处 《水处理技术》 CAS CSCD 北大核心 2022年第5期141-144,共4页 Technology of Water Treatment
关键词 反渗透脱盐率 氧化 背压破坏 探针实验 reverse osmosis desalination rate oxidation back pressure damage probe test
  • 相关文献

参考文献10

二级参考文献29

  • 1李传涛.膜法水处理技术在生活污水深度处理中的应用分析[J].科技经济导刊,2019,0(32):92-92. 被引量:5
  • 2徐晓莉,尹连庆,夏君旨.反渗透技术在水处理中的应用研究进展[J].中国电力教育,2005(z2):10-11. 被引量:8
  • 3赵雪莲,徐岩,李国星.反渗透膜的技术经济指标评测[J].现代化工,2011,31(S2):1-4. 被引量:2
  • 4高从堦,陈国华.海水淡化技术与工程手册[M].北京:化学工业出版社,2004:55-121.
  • 5FLIMTEC反渗透和纳滤膜元件产品与技术手册.2011.
  • 6GB-19923-2005城市污水再生利用工业用水水质[S].
  • 7Dow Chemical Company. A comparison of cellulose acetate and FILMTEC FTS0 Membranes. Form No. 609-00252-604 [EB/OL]. (2005.6) http: //www.dow.condscripts/litorder.asp?filepath =liqui- dseps/pdfs/noreg/609-00232.pdf.
  • 8Dow Chemical Company. FILMTEC reverse osmosis membranes. Te- chnical manual. Chl.4 Membrane Description [EB/OLj. (2005.7) http : jjwww.dowwaterandprocess.com/en/resources/reverse-osmosis- technical-manual.
  • 9Cardona E, Piacentino A, Marchese F. Energy saving in two-stage reverse osmosis systems coupled with uhrafiltration processes [J]. Desalination ,2005,184( 1 ) : 125-137.
  • 10冉祥军,杜海波,刘建军.纳滤膜污染原因分析及运行管理[J].工业水处理,2009,29(1):86-89. 被引量:6

共引文献46

同被引文献86

引证文献6

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部