摘要
石油化工装置为了降低发生火灾后的损失和影响而设置了防火隔离阀,依据防火隔离阀的防火要求需要对其执行机构安装防火罩。本文对比分析了柔性防火罩和刚性防火罩的结构形式和特点,并简要介绍了几个石油化工装置常用的防火罩品牌,重点阐述了防火罩设计和安装时的注意事项和问题解决方法,最后对防火罩结构形式的选择给出了建议。
In order to reduce the loss and influence by fire in the petrochemical plant, fire isolation valve is set up. According to the requirement of flameproof,fire isolation valve’s actuator needs to install flameproof enclosure. The structure and characteristics of flexible flameproof enclosure and rigid flameproof enclosure are analyzed contrastively. Several brands of flameproof enclosure used frequently in petrochemical plant are introduced briefly. Some cautions and solutions of design and installation of flameproof enclosure are elaborated, and suggestions are put forward for the choice of structure of flameproof enclosure finally.
作者
王恒伟
Wang Hengwei(CNOOC Huizhou Petrochemicals Company Limited,Huizhou 516086,China)
出处
《广东化工》
CAS
2022年第7期168-169,共2页
Guangdong Chemical Industry
关键词
石油化工装置
防火隔离阀
执行机构
柔性防火罩
刚性防火罩
petrochemical plant
fire isolation valve
actuator
flexible flameproof enclosure
rigid flameproof enclosure