摘要
苯乙烯装置乙苯过热器(E-001)运行参数与设计值存在较大偏差,导致苯乙烯装置一直未能达到设计负荷。列出乙苯过热器运行异常的可能原因,并进行深入分析。通过分析,排除大流量泄露或换热面积不够的原因,可能原因为仪表计量不准确。建议在装置检修期间对现场流量/温度仪表进行进一步核验。
The operating parameters of ethylbenzene superheater(E-001)in Styrene unit deviate greatly from the design value,resulting in the failure of styrene unit to reach the design capacity.The possible causes of abnormal operation of ethylbenzene superheater are listed and analyzed in depth.Through analysis,the causes of large flow leakage or insufficient heat exchange area are eliminated.The possible cause is inaccurate instrument measurement.It is recommended to further verify the on-site flow/temperature instruments during plant maintenance.
作者
郭振国
Guo Zhenguo(CNOOC Petrochemical Engineering Co.,Ltd.,Jinan 250101,China)
出处
《山东化工》
CAS
2022年第7期156-157,160,共3页
Shandong Chemical Industry
关键词
苯乙烯
乙苯过热器
仪表
styrene
ethylbenzene superheater
instrument