期刊文献+

水泥窑旁路放风系统及其工艺设计 被引量:1

Cement Kiln Bypass System and its Technological Design
下载PDF
导出
摘要 介绍了不同粉尘捕集方式下,水泥窑窑尾旁路放风系统各工艺流程的优缺点,以及进行旁路放风系统设计时的放风量选择及其具体设计要求。当放风比例<25%时,取风点宜设置在回转窑一侧中心位置;进入骤冷室之前的管道一般需设置230mm厚的浇注料,进风口风速一般按20m/s设计,出风口风速一般按18m/s设计,骤冷室至收尘器进风口的烟气管道长度须≥20m。 This paper introduces the advantages and disadvantages of each technological process of the bypass system at the kiln inlet chamber of cement kiln under different dust capture methods,as well as the selection of venting volume and its specific design requirements when designing the bypass system.When the bypass ratio is less than 25%,the flue gas intake point should be set at the center on the side of the rotary kiln;the pipeline before entering the quenching chamber generally needs to be set with castable in a thickness of 230mm;the gas speed at the inlet is generally designed at 20m/s,and the gas speed at the air outlet is generally set at 18m/s.The length of the flue gas pipeline from the quenching chamber to the air inlet of the dust collector would be more than 20m.
作者 黄海林 姜树丰 郝利炜 刘鹏飞 王小文 HUANG Hailin;JIANG Shufeng;HAO Liwei;LIU Pengfei;WANG Xiaowen(Beijing Building Materials Academy of Science Research Co.,Ltd.,Beijing 100041,China)
出处 《水泥技术》 2022年第3期68-73,共6页 Cement Technology
关键词 水泥窑窑尾 旁路放风 放风量 取风点 kiln inlet chamber bypass bypass volume flue gas intake point
  • 相关文献

参考文献3

二级参考文献1

共引文献16

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部