摘要
在邯济线扩能改造信号设备施工过程中,LKJ-2000型列车运行监控记录装置过机不校,导致数据距离不准的情况。研究LKJ-2000型列车运行监控记录装置过机校正原理,分析过机校正的处理方式和过程,并查找出造成邯济线过机不校的原因,从而对分析LKJ过机校正不良提供参考和思路。
In the construction of signal equipment for Handan-Jinan Railway expansion and reconstruction,the distance is not accurate due to that the locomotive directly passed over the signal without distance correction by LKJ-2000.In order to find out the reason,this paper analyzes the principle,processing mode and procedure of distance correction of LKJ-2000 when locomotive passing over signal,which can provide reference and analysis method for the distance correction failure of LKJ when passing over signal.
作者
黄天天
李新健
刘明源
Huang Tiantian;Li Xinjian;Liu Mingyuan(Beijing Huatie Information Technology Co.,Ltd.,Beijing 100081,China;Jinan Signaling&Communication Depot,China Railway Jinan Group Co.,Ltd.,Jinan 250001,China)
出处
《铁路通信信号工程技术》
2022年第5期90-95,共6页
Railway Signalling & Communication Engineering
关键词
列车运行监控记录装置
过机不校
轨道信号
载频泄漏
LKJ
passing over signal without distance correction
track signal
carrier frequency leakage